My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
21-1425
Zephyrhills
>
Building Department
>
Permits
>
2021
>
21-1425
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/9/2022 7:26:00 AM
Creation date
5/9/2022 7:25:59 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
21-1425
Building Department - Name
PACHECO,ANGEL & DONNA
Address
5504 5TH ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S' <br /> IVALUATION REPORT Number: IF <br /> o Originally Issued: 02/11/2-020 Valid Through: 02/28/2021 <br /> TABLE 2-HP288 WITH RETROFIT BRACKET-ASD COMPRESSION CAPACITIES <br /> Allowable Compression Capacity(kips) <br /> Bracket Part , Helix(P3)4 Soil FOS=2 Soil Foundation Foundation <br /> 1 Sleeve Part No. Bracket Description Bracket Shaft <br /> No. (P1)2 (P2)3 .(Per Helix (P4)5 FOS=2.5 System with System with <br /> Plate) (P4)5 Soil FOS=26 Soil FOS=2.56 <br /> FS288BL2 FS288ES30 HP288 Low Profile 2 24.0 63.6 40.0 35.5 28.4 24.0 24.0 <br /> FS288BL2-G FS288ES30-G Bracket w/30"sleeve 26.8 1 71.1 40.0 35.5 28.4 26.8 26.8 <br /> For SI:1 inch=25.4 mm,1 kip=1000 Ibf=4.448 kN <br /> 'Part numbers with"G"suffix indicate hot-dip galvanized coating.Part numbers without a"G"suffix indicate plain steel. <br /> 2Bracket capacities are based on full scale load tests and assumes a minimum concrete compressive strength(f c)of 2,500 psi(17.24 MPa). <br /> 3Shaft capacities are limited to foundation systems with fully braced shafts as described in Section 3.1.2 of this report. <br /> 4Helix capacity is based on a single helix plate with outer diameter of 8,10,12 or 14 inches(203 mm,254 mm,305 mm,or 356 mm). <br /> 5Soil capacity is derived from torque correlation calculations per Section 3.1.1 of this report,with piles installed at the maximum torsion rating. <br /> 6Foundation system allowable capacities are based on the lowest of P1,P2,P3 and P4 listed in this table. <br /> Nuts each end <br /> (HWH8N-Z-075) <br /> Cap <br /> (FS288C) <br /> 'EXISTING <br /> Threaded Rod :STRUCTURE <br /> (HWTRS210-Z-075=16) <br /> Low Profile 2 Bracket <br /> (FS288BL2) <br /> ,• ' �,%j/\,f.\i� I .mil j\;.. <br /> 30'Sleeve <br /> (FS288ES30)' <br /> Pier Shaft Coupler <br /> Coupler Bolts and <br /> (HWS5&Z-075.425 <br /> and HWSJ5N-Z-075) <br /> FIGURE 1-FS288131_2 RETROFIT BRACKET AND SHAFT ASSEMBLY <br /> TABLE 3-HP288 WITH NEW CONSTRUCTION BRACKET-ASD COMPRESSION CAPACITIES <br /> Bearing Plate <br /> Minimum Edge Allowable Compression Capacity(kips) <br /> Concrete Helix(P3)4 Soil Soil Foundation Foundation <br /> Bracket Part No.' Dimensions Distance Bracket Shaft <br /> (in) Compressive "A"(in) (Pl)2 (P2)3 (Per Helix F05=2 FOS=2.5 System with System with <br /> Strength(psi) Plate) (P4)5) (P4)5 Soil FOS=26 Soil FOS=2.56 <br /> HP288NCB or 2500 3 33.1 63.6 40.0 35.5 28.4 33.1 28.4 <br /> HP288NCB-G 6 x 6 x 0.75 >_4 44.1 63.6 40.0 35.5 28.4 35.5 28.4 <br /> 3000 2 3 39.7 63.6 40.0 35.5 28.4 35.5 28.4 <br /> HP288NCB8 or 8 x 8 x 1.75 2500 >_4 43.1 63.6 40.0 35.5 28.4 35.5 28.4 <br /> HP288NCB8-G <br /> For SI:1 inch=25.4 mm,1 kip=1000 Ibf=4.448 kN <br /> 'Part numbers with"G"suffix indicate hot-dip galvanized coating.Part numbers without a"G"suffix indicate plain steel. <br /> 2Bracket capacity is based on concrete bearing strength only.All other design provisions related to the concrete foundation,such as punching shear, are outside the scope <br /> of this evaluation report,and shall be determined in accordance with ACI 318. <br /> 3Shaft capacities are limited to foundation systems with fully braced shafts as described in Section 3.1.2 of this report. <br /> 4Helix capacity is based on a single helix plate with outer diameter of 8,10,12 or 14 inches(203 mm,254 mm,305 mm,or 356 mm). <br /> sSoil capacity is derived from torque correlation calculations per Section 3.1.1 of this report,with piles installed at the maximum torsion rating. <br /> 6Foundation system allowable capacities are based on the lowest of P1,P2,P3 and P4 listed in this table. <br /> Page 6 of 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.