Laserfiche WebLink
23. Tamper- Resistant Receptacles in accordance with 406.�11 of,the.2016 NEC <br /> 24. In accordance with the Land Development Code,lots-shall be soddedbefore final of least.l0_ <br /> feet around the structure: . <br /> 25:.R403.5.3Hot W6ter.pipe insulation . . <br /> Insulation for hot.Water.'pipe.with a minimum-thermal resistance (R-value) of:R-3.shall.be applied to the <br /> following:: <br /> Piping V,inch (-1.9.1 mm)and larger in:nominal diameter. <br /> Piping,serving more than:one dwelling'unit: <br /> Piping located outside the conditioned space: <br /> Piping from the:water'heater to:a'distribution manifold.. <br /> Piping-located under,a floor slab: <br /> Buried in piping. <br /> Supply and return piping in recirculation-systems other than demand recirculation systems: <br /> 25:Blower door test shall be provided:before C.O: . <br /> :26.A copy of the enerzy eacls'shall be:ivith wermit at all times. <br /> 27.. Cop*of.-final.insulation report shalhbe provided with Permit before fnaL <br /> 28.No fence, pool or screen enclosurejs issued with:this-permit. <br /> RE:-Finished Floor Elevation <br /> F.B.C-..Florida Building Code th Edition <br /> R:O.W:-Right of Way.. <br /> A.D.A.- Americans with Disabilities Act., N.E.C.-National Electric Code (2016) <br />