1 <br /> D_ <br /> Q <br /> 6 Y <br /> . . Single Family Dwelling <br /> Plan Review Comments <br /> 1. F:RE...shall be a minimum of 8" above the road elevation and an engineered site plan. <br /> 2: Lots shall be graded to comply with R461.3.'of the F.B.C: <br /> 3: Compaction test required if 24"or more of fill.dirt is brought in at any one place. <br /> 4: Tie in survey required before-pouring concrete. <br /> 5. Driveways require a R.O.W. use permit: All 4 sides.of driveway_ thra the sidewalk shall have <br /> expansion material.. <br /> 6! All setbacks shall be met. <br /> T. All property markers sliall be uncovered_and marked at time of first inspection. <br /> 8: All A.D.A.'requirements shall be met: . <br /> 9. No electric,.plumbing;mechanical,or framing shall be:covered without an inspection.and <br /> approval first: <br /> 1b. All Garages shall comply with section:R302.6 of the F.B:C. (Fire Separation). <br /> 11. Appliances shall not be installed in a location where subject to mechanical damage unless <br /> protected by approved barriers. M303.4 of the F.B.0 <br /> 12. Water heaters shall'comply with section P607.3 of the F.B.C. <br /> 13. Foundation supports for A/C units shall be raised at least 3" above finished glade. M1308.:1 . <br /> 14. Return air in all bedrooms. F.B.C. M1620.4 <br /> 1.5. Smoke detectors.are to be installed in accordance with R313-.1 of the F.B.C. <br /> 16;All glazing requirements are to be-in accordance with R308.4.of the F.B.C: <br /> 17. All means of egress are to be in accordance with R311 of the F.B.C. <br /> 18. "Green gypsum board"shall riot be used as a backer in showers or tubs:R702.4.2 F.B.C. <br /> 10. Combin'atiori-type AM breakers are required at all locations requiring an AFCI type breaker. <br /> 20. Carbon monoxide alarms will:be required in new construction that.uses fossil-burning heating <br /> or appliances or an attached garage. They shall be installed in accordance with the F.B.C. <br /> 21. All plumbing, mechanical; and electrical shall be separate from unit to unit. This includes all <br /> underground:plumbing and electric. <br /> 21 All 2U6 N:E.C. Codes will be enforced. <br />