Laserfiche WebLink
Interior: Ceiling <br /> Figure 8:Wall and Ceiling Destruction from Car Crash <br /> As per Figure 5 and Figure 6,there has been significant damage to the interior non load bearing <br /> wall within the apartment complex. As a result,this has caused the door frame, leading into the <br /> bedroom,to start to collapse. In addition,there is cracking along the corner of the wall that can <br /> be seen in figure 7. Also, parts of the ceiling have been damaged due to the upward force of the <br /> sheet rock and wall studs pushing into the ceiling. The wall is in-between the two trusses above. <br /> No damage was observed to the trusses. After demolition contractor shall verify that no damage <br /> has taken place to the trusses. Contact Advanced Engineering,to speak with Engineer of record <br /> for any new findings. <br /> 2651 Narnia Way, Unit 102,Land O Lakes, FL 34638 Page 8 of 12 <br /> Advanced Engineering Consultants LLC,321-794-6465 <br />