Laserfiche WebLink
FORM R405-2020 STATE COPY <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: KH02743 Ivanhoe(TAM) Builder Name: K Hovnanian Homes <br /> Street: 6825 Shelby Lynn Way Permit Office: City of Zephyrhills <br /> City,State,Zip: Zephyrhills,FL,33542 Permit Number: <br /> Owner: Jurisdiction: <br /> Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 10. Wall Type$2785.3 sqft.) Insulation Area <br /> 2. Single family or multiple family Detached a. Frame-Wood,Exterior R=11.0 1312.00 ft2 <br /> b.Concrete Block-Int Insul,Exterior R=4.1 1112.20 ft2 <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 361.11 ft2 <br /> 4. Number of Bedrooms 5 d.N/A R= ft2 <br /> 5. Is this a worst case? Yes 11.Ceiling Types (1610.0 sqft.) Insulation Area <br /> a.Under Attic(Vented) R=30.0 1610.00 ft2 <br /> 6. Conditioned floor area above grade(ft2) 2666 b.N/A R= ft2 <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 <br /> 7. Windows(211.1 sqft.) Description Area 12.Ducts R ft2 <br /> a. U-Factor: Dbl,U=0.34 109.75 ft2 a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 274.3 <br /> SHGC: SHGC=0.23 <br /> b. U-Factor: Dbl,U=0.34 61.19 ft2 13.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.29 a.Central Unit 33.1 SEER:15.00 <br /> c. U-Factor: Dbl,U=0.63 40.20 ft2 <br /> SHGC: SHGC=0.32 14.Heating systems kBtu/hr Efficiency <br /> Area Weighted Average Overhang Depth: 1.000 ft. a.Electric Heat Pump /hr HSPF:8.50 <br /> Area Weighted Average SHGC: 0.265 <br /> 8. Skylights Area <br /> c. U-Factor:(AVG) . N/A ft2 15.Hot water systems <br /> SHGC(AVG): N/A a.Electric Cap:50 gallons <br /> 9. Floor Types (2666.0 sqft.) Insulation Area EF:0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1131.00 ft2 b. Conservation features <br /> b.Floor Over Other Space R=0.0 1056.00 ft2 None <br /> c.other(see details) R= 479.00 ft2 16.Credits Pstat <br /> Glass/Floor Area: 0.079 <br /> Total Proposed Modified Loads: 80.93 PASS <br /> Total Baseline Loads: 80.61 <br /> I hereby certify that the plans and specifications covered by Review of the plans and O�Z14E S744 <br /> this calculation are in compliance with the Florida Energy specifications covered by this <br /> Code. calculation indicates compliance <br /> with the Florida Energy Code. ti rr�r, , •' f ,° ,;,,, O <br /> PREPARED BY: Before construction is completed <br /> DATE: ?_1_ n24 this buildingwill be inspected for <br /> P <br /> compliance with Section 553.908 t. <br /> hereby certify that this building, as designed, is in compliance Florida Statutes. <br /> with the Florida Energy Code. CODS <br /> OWNER/AGENT:- Sara.7'.iZ0Ve1a. BUILDING FI�I/,�L:ZU <br /> DATE: 2/8/2021 DATE: <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.3.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an <br /> envelope leakage test report with envelope leakage no greater than 5.60 ACH50(R402.4.1.2). <br /> 1/25/2021 1:51 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 5 <br />