Laserfiche WebLink
STATE COPY <br /> FORM R405-2020 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: KHO1830 Dupont(TAM) Builder Name: K Hovnanian Homes <br /> Street: 6816 Shelby Lynn Way Permit Office: City of Zephyrhills <br /> City,State,Zip: Zephyrhills,FL,33542 Permit Number: <br /> Owner: Jurisdiction: <br /> Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 10. Wall Type>l692.9 sqft.) Insulation Area i <br /> 2. Single family or multiple family Detached a.Concrete Block-Int Insul,Exterior R=4.1 1412.70 ft2 <br /> b.Frame-Wood,Adjacent R=11.0 280.22 ftZ <br /> 3. Number of units,If multiple family 1 c.N/A R= ftZ <br /> 4. Number of Bedrooms 4 d.N/A R= ft2 <br /> 11.Ceiling Types (1830.0 sqft.) Insulation Area <br /> 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1830.00 ftZ <br /> 6. Conditioned floor area above grade(ft2) 1830 b.N/A R= ft2 <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 <br /> 7. Windows(158.1 sqft.) Description Area 12.Ducts R ft2 <br /> a. U-Factor: Dbl,U=0.34 101.94 ft2 a.Sup:Attic,Ret:Main,AH:Main 6 250 <br /> SHGC: SHGC=0.23 <br /> b. U-Factor: Dbl,U=0.63 40.00 ft2 13.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 26.9 SEER:15.00 <br /> c. U-Factor: Dbl,U=0.34 16.19 ft2 <br /> SHGC: SHGC=0.29 14.Heating systems kBtu/hr Efficiency <br /> Area Weighted Average Overhang Depth: 3.530 ft. a.Electric Heat Pump 28.0 HSPF:8.50 <br /> Area Weighted Average SHGC: 0.259 <br /> 8. Skylights Area <br /> c. U-Factor:(AVG) N/A ft2 15.Hot water systems <br /> SHGC(AVG): N/A a.Electric Cap:50 gallons <br /> 9. Floor Types (1830.0 sqft.) Insulation Area EF:0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1830.00 ft2 b. Conservation features <br /> b.N/A R= ft2 None <br /> c.N/A R= ft2 16.Credits Pstat <br /> Glass/Floor Area: 0.086 Total Proposed Modified Loads: 56.64 PASS <br /> Total Baseline Loads: 56.44 <br /> I hereby certify that the plans and specifications covered by Review of the plans and O�T)il3 Sxq?� <br /> this calculation are in compliance with the Florida Energy specifications covered by this y z: O <br /> Code. calculation indicates complianceK+ <br /> �i with the Florida Energy Code. <br /> PREPARED BY: /l�.L� .A ��� Before construction is completed <br /> DATE: 2-1-200 this building will be inspected for ) ` _- <br /> compliance with Section 553.908 * 11 <br /> herebycertify that this building, as designed, is in compliance Florida Statutes. <br /> fY 9, 9 p <br /> with the Florida Energy Code. OD WE <br /> OWNER/AGENT: sCWa VRLVera. BUILDING OFFICIAL: <br /> DATE: 2/8/2021 DATE: <br /> - Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as <br /> certified factory-sealed in accordance with R403.3.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an <br /> envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). <br /> 1/25/2021 12:16 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 4 <br />