4 <br /> Single .Family Dwelling <br /> Plan Review Comments <br /> 1. F.F.K.shall..be a minimum of-8" above the road elevation and an engineered site plan. <br /> 2. Lots shall be graded to comply with R401.3 of the F:B.C. <br /> 3. Compaction test required if 24"or more of fill dirt is brought in at any one place. <br /> 4: Tie in survey required before pouring concrete. <br /> 5. Driveways regiiire.a R.O.W. use permit. All 4 sides of driveway thru the sidewalk shall have <br /> expansion material.. <br /> 6. All setbacks shall be rivet. <br /> 7:. All property markers shall be uncovered.and marked at time of first inspection_. <br /> 8 All'A.D.A.requirements shall be,met: <br /> 9: No electric,plumbing;mechMical, or.framing shall.be covered without an-inspection and <br /> approval first: <br /> 10:.All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation): <br /> 11. Appliances shall not be installed in a location.where_subiect.to-mechanical.damage unless <br /> protected by approved barriers. M3034 of the F.B.0 <br /> 12. Water heaters'shall comply with section P607.3 of the F.B.C. <br /> 13. Foundation supports for A/C tinits;.shall.be raised at least 3" above f nished grade. M 1308:1_ <br /> 14: Return air in all bedrooms. F.B.C. M1620.4 <br /> 15. Smoke detectors.are to be installed in accordance with R313:1 of the F.B.C. <br /> 16: All glazing requirements are to be in accordance.with R308.4.6f the F.B.C. <br /> . . <br /> 17. All means.of egress are to be in accordance with RM I of the F.B.C. <br /> 18. "Green gypsum board" shall not be used as a backer in showers or tubs. R702:4.2 F.B.C. <br /> 19. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. <br /> 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating <br /> or appliances or an attached garage. They shall be installed in accordance with the F.B.C: <br /> 21. All plumbing,mechanical, and electrical shall be separate from unit to unit: This includes all <br /> underground plumbing and.electric. <br /> 21 All 2016 N.E.C. Codes will be enforced. <br />