My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
21-1531
Zephyrhills
>
Building Department
>
Permits
>
2021
>
21-1531
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/9/2022 10:28:29 AM
Creation date
5/9/2022 10:28:29 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
21-1531
Building Department - Name
PERRONE,JOYCE
Address
5410 TANGERINE DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SUPPLY & MANUFACTURING <br /> PIPI <br /> R VA L G61iCozk <br /> GULFF": RTM <br /> PLYWOOD26 GLIAGE GULIFPBR TM PANEL OVER 15/32" <br /> FLORIDA PRODUCT APPROVAL NO. 11651.19 R3 <br /> TM <br /> Compliance Statement: The product as described in this report has demonstrated compliance with the <br /> Florida Building Code 2017, Sections 1504.3.2, 1518.9, 1523.6.5.2.4. <br /> Product Description: GuIfPBRTm Roof Panel, Minimum 26 Ga. Steel, 36" Coverage, through <br /> fastened roof panel over minimum 15/3z" Plywood Decking. Non Structural <br /> application. <br /> Panel Material/Standards: Material: Minimum 26 Ga. Steel, ASTM A792 or ASTM A653 G90 conforming to <br /> Florida Building Code 2017 Section 1507.4.3. <br /> Paint Finish Optional <br /> Yield Strength: Min. 80.Oksi <br /> Corrosion Resistance: Panel Material shall comply with Florida Building <br /> Code 2017, Section 1507.4.3. <br /> Panel Dimension(s): Thickness: 0.018" Minimum <br /> Width: 36" Coverage <br /> Rib Height: 1�'/a" Tall Rib at 12" O.C. <br /> Panel Fastener: #9-15x1.5" with sealing washing, 1/a-14 x 7/8" HWH Lap Screw with sealing <br /> washer at 24" O.C. Maximum at the panel side laps or approved equals <br /> 1/4" minimum penetration through plywood. <br /> Corrosion Resistance: Per Florida Building Code 2017, Section 1506.6, 1507.4.4 <br /> Substrate Description: Minimum 15/32" thick, APA Rated plywood over supports at maximum 24" O.C. <br /> Design of plywood and plywood supports are outside the scope of this <br /> evaluation. Must be designed in accordance w/Florida Building Code 2017. <br /> Design Uplift Pressures: Table"A" <br /> Maximum Total Uplift Design Pressure 60.5 psf 154.75 psf <br /> Fastener Pattern 12"-12"-12" 7"-5"-7"-5"-7" <br /> Fastener Spacing 2411 <br /> Design Pressure includes a Safety Factor=2.0. <br /> FL#11651.19 R3•OCTOBER 5,2017 <br /> . ® • EVALUATI1101114REPORT <br /> ENGINEERING,KUHN <br />
The URL can be used to link to this page
Your browser does not support the video tag.