Laserfiche WebLink
m. <br /> Q <br /> Single Farnil yDWelling <br /> Plan Review Comments . <br /> L* F:F.E.shall'be a minimum of 8 above the road elevation and an engineered site plan. <br /> 2: .Lots shall be graded to.comply with R401:3 of the F:B.C: <br /> Compaction test required.if 24"or more of fill_dirk is brought in at any one place: <br /> 4:: _Tie iri survey re..quired before.pouririg concrete. <br /> .5; Driveways require.a R.O.W. use permit. All 4 sides-of driveway thra the sidewalk shall have <br /> expansion material.; <br /> 6: .All setbacks shall be met. <br /> 7::.All ro ert markers shall be uncovered.arid:maeked at time:of first inspection. . <br /> P p. ..Y . <br /> 8:- -All A:D.A. requirements shall be met: <br /> 9; No electric,:plumbing;mechanical, or-framing shall be covered without an inspection and . <br /> approval first: <br /> 10: All Garages shall comply with section R302.6 of the EB:C. (Fire Separation): <br /> 11. Appliances.shall not be installed in a location.where subject to mechanical.damage unless <br /> protected by.approved barriers. M303:4 of the'F:B:C_ <br /> 12. Waterheaters'shali.comply with section P607.3 ofthe'F:B:C: <br /> 13.Foundation supports for A/C uriiis;shall be raised at least'3" above finished grade. M1308.1 <br /> 14. Return air in all bedrooms. F.B.C.- M1620.4 <br /> 1.5. Smoke detectors.are to be installed in accordance with R3-13 j bf.the F.B.C. <br /> 16: All glazing requirements are to be:iri accordance�:with R308.4 of the E&C. <br /> 17. All means of egress are to bean accordance with R311 of the F.B.C: . <br /> 18. "Green gypsum board" shall tint be used as a backer-in showers or tubs.R702:4:2 F.B.C. <br /> 19: Combination-type AFCI breakers are required at all locations requiring an AFCI.type breaker. <br /> 20. Carbon monoxide alarms will be required iri neW construction that.uses fossil-burning heating. <br /> or appliances or an,attached garage.' They shall be installed in accordance with the F.B.C. <br /> 2L.All plumbing,mechanical, arid electrical shall b.e separate from unit to unit: This includes all <br /> underground.plumbing and electric. <br /> 22. All 2016 N.E.C. Codes will be enforced. <br />