Laserfiche WebLink
s` <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. F:RE.. shall:be a minimum of 8"above the road elevation and an engineered site plan. <br /> 2' Lots shall be graded to comply with R401:3 of the F.B.C. . <br /> 3. Compaction test required if 24"or more of fill dirt is brought in at any one place. <br /> 4: Tie in survey required before pouring concrete. <br /> 5. Driveways require.a R.O.W. use permit: All 4 sides of driveway thru the sidewalk shall have <br /> expansion material.- <br /> 6: All setbacks shall be-net. <br /> 7'. All property markers shall be uncovered,and marked at time of first inspection. <br /> 8: A11 A..D.A.requirements shall be met: <br /> 9: No electric,.plumbing;mechanical, or framing shall.be:covered without an inspection.and . <br /> approval first. <br /> 10. All Garages shall comply.with section R302.6 of the F.B.C. (Fire Separation). <br /> 11. Appliances shall not b.e installed in a location where subject to mechanical damage unless <br /> protected by approved barriers. M303.4 of the RB.0 <br /> 12. Water heaters shall coinply with section P607.3 of the F.BC. <br /> I 116undation,supports for A/C units:shall be raised at least 3" above finished grade. M 1308:1 <br /> 14: Return air in all bedrooms. F.B:C. M16M. <br /> .. <br /> 1.5. Smoke detectors are to be,installed in accordance with RM3:Lof.the,F.B.C. <br /> 16: All glazing requirements are to be in accordance with R308A of the F.B.C: <br /> . .. <br /> 17. All means of egress are to be'in accordance with R311 of the F.B.C. <br /> 18. "Green gypsum,board'.' shall riot be used as a backer in showers or tubs. R702:4:2 F B.C. <br /> 19. Combiriation-type AMbreakers are required at all locations requiring an AFCI type breaker. <br /> 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating <br /> or appliances or an attached garage.- They shall be installed in accordance with the FB.C: <br /> 21. All plumbing, mechanical; and electrical shall be separate from unit to unit. This includes all <br /> uiiderground plumbing and electric. <br /> 22. All 201:6 M.E.C. Codes will be enforced. <br />