<br /> ONEMOjetc.
<br /> TABLE 21: STEEL.• • CONSTRUCTION, ••• e OR RECOVER
<br /> SYSTEM TYPE D-1: MECHANICALLY ATTACHED ROOF COVER
<br /> Insulation(Note 13) Roof Cover(Note 15)
<br /> System Deck MDP
<br /> No. (Note 1) Type Attach Membrane Fasteners(Note 11) Attachment (pef)
<br /> (Note 5).
<br /> EVERGUARD TPO:
<br /> ,_..,..,. D�iilTec XHD'witliDtiilTec.2 3y$in. arbed X J Pl tes L8sihcM o:e;within_6hnchiwitle laps spaced
<br /> Miri 22"a:,t e B Orieiotmoie,layers,:any Prelim: :""OF'ON � F:„ _ :.q .; ,„;
<br /> 5=416. _ v>g;U Yp = ,. EverGuard TPO or-1 Tec.#15.EHD;Fastener::with.Drill fec 2.4"Barbed 54 nch"o.c:.and sealed.wrth.aal.5-irtch•h�ea� 0:0
<br /> Grade 80steel com6+nat+0 min_1-inch attach :, T Si
<br /> Drill" ecT 2.4 Scoop Seam Plate tweld�
<br /> Drill-Tec XHD with Drill-Tec 2-3/8 In.Barbed XQPlates 12-inch o.c.within 6-inch wide laps spaced
<br /> S-417. Min.22 ga.,type B, One or more layers,any Prelim. EverGuard TPO or Drlll-Tec Eyehook AccuSeam Plates or Drlll-Tec#15 114-Inch o.c.and sealed with a 1.5-Inch -30.0
<br /> Grade 33 steel combination,min.1.5-inch attach EHD Fastener with Drill-Tec 2.4"Barbed Seam Plate or heat weld.
<br /> Drill-Tec 2.4"Scoop Seam Plate
<br /> Min.22 ga.,type B, One or more layers,any Prelim. Drill-Tec XHD with Drill-Tec 2 in.Double Barbed XHD 12-Inch o.c.within 5-inch wide laps spaced
<br /> S-418. Grade 80 steel combination,min.1.5-inch attach EverGuard TPO Plates 115-inch o.c.and sealed with a 1.5-inch -30.0
<br /> heat weld.
<br /> Drill-Tec XHD and Drill-Tec 2 In.Double Barbed XHD
<br /> Min.22 ga.,type B, One or more layers,any Prelim. Plates,Drill-Tec 2-3/8 In.Barbed XHD Plates,Drill-Tec 12-Inch o.c.in rows spaced max.114-inch
<br /> S-419. EverGuard TPO Eyehook AccuSeam Plates or Drill-Tec#15 EHD Fastener o.c. An 8-inch wide cover strip is heat -30.0
<br /> Grade 33 steel combination,min.1.5-inch attach with Drill-Tec 2.4"Barbed Seam Plate or Drill-Tec 2.4" welded over the stress plates.
<br /> Scoop Seam Plate,
<br /> Min.22 ga.,type B, One or more layers,any Prelim. Drill-Tec SXHD with Drill-Tec 2 3/4 in.Barbed SXHD 12-Inch o.c.within 6-Inch wide laps spaced
<br /> S-420. Grade 33 steel combination,min.1-Inch attach EverGuard TPO Plates 138-inch o.c.and sealed with a 1.5-Inch -30.0
<br /> heat weld.
<br /> Min.22 ga.,type B, One or more layers,any Prelim. Drill-Tec XHD with Drlll-Tec 2-3/8 In,Barbed XHD Plates 12-Inch o.c.within 6-Inch wide laps spaced
<br /> S-421. Grade 60 steel combination,min.1-Inch attach EverGuard TPO or Drill-Tec#15 EHD Fastener with Drill-Tec 2.4"Barbed 138-inch o.c.and sealed with a 1.5-inch -30.0
<br /> Seam Plate or Drill-Tec 2.4"Scoop Seam Plate heat weld.
<br /> Min.22 ga.,type B, One or more layers,any Prelim. Drill-Tec XHD or Drill-Tec SXHD with Drill-Tec 2 3/4 in. 12-Inch o.c.within 6-Inch wide laps spaced
<br /> S 422• Grade 80 steel combination,min.1-inch attach EverGuard TPO Barbed SXHD Plates 138-inch o.c.and sealed with a 1.5-Inch -30.0
<br /> heat weld.
<br /> Drill-Tec XHD and Drill-Tec 2In.Double Barbed XHD
<br /> Min.22 ga.,type B, One or more layers,any Prelim. Plates,Drill-Tec 2-3/8 In.Barbed XHD Plates,Drill-Tec 6-Inch o.c.within 6-inch wide laps spaced
<br /> S-423. EverGuard TPO Eyehook AccuSeam Plates or Drill-Tec#15 EHD Fastener 138-inch o.c.and sealed with a 1.5-inch -30.0
<br /> Grade 33 steel combination,min.1-Inch attach with Drill-Tec 2W'Barbed Seam Plate or Drill-Tec 2.4" heat weld.
<br /> Scoop Seam Plate
<br /> Min.22 ga.,type B, One or more layers,any Prelim. Drill-Tec XHD with Drill-Tec 2 In.Double Barbed XHD 12-Inch o.c.within 6-inch wide laps spaced
<br /> S 424. Grade 33 steel combination,min.1-Inch attach EverGuard TPO Plates 90 Inch o.c.and sealed with a 1.5 Inch heat 37.5
<br /> weld.
<br /> Min.22 ga.,type B, One or more layers,any Prelim. Drill-Tec SXHD with Drill-Tec 2 3/4 In.Barbed SXHD 12-Inch o.c.within 6-Inch wide laps spaced
<br /> S-425. Grade 40 steel combination,min.1-Inch attach EverGuard TPO Plates 114-inch o.c.and sealed with a 1.5-inch -37.5
<br /> heat weld.
<br /> NEMO ETC,LLC Evaluation Report 01506.09.05-R44 for FL5293-1143
<br /> Certificate ofAuthorizatlon#32455 7"'Edition(2020)FBC NON-HVHZ EVALUATION Revision 44:10/15/2020
<br /> 02019 NEMO ETC,LLC GAF EverGuard TPO Single-Ply Roof Membrane Systems;(800)766-3411 Appendix 1,Page 67 of 127
<br />
|