My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
21-1541
Zephyrhills
>
Building Department
>
Permits
>
2021
>
21-1541
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/9/2022 10:33:56 AM
Creation date
5/9/2022 10:33:54 AM
Metadata
Fields
Template:
Building Department
Company Name
DR HORTON
Building Department - Doc Type
Permit
Permit #
21-1541
Building Department - Name
DR HORTON
Address
7116 STEER BLAD DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT <br /> WALLS <br /> Adjacent Space Cavity Width Height Sheathing Framing Solar Below# Ornt To Wall Type <br /> 1 N=>W Exterior Concrete Block-Int Insul Main 4.0999 20 4 9 4 189.8 ftz 0 0.6 0 <br /> 2 E=>N Exterior Concrete Block-Int Insul Main 4.0999 64 1 9 4 598.1 ftz 0 0.6 0 <br /> 3 S=>E Exterior Concrete Block-Int Insul Main 4.0999 50 0 9 4 466.7 ftz 0 0.6 0 <br /> 4 W=>S Exterior Concrete Block-Int Insul Main 4.0999 74 0 9 4 690.7 ftz 0 0.6 0 <br /> 5 N=>W Garage Frame-Wood Main 13 29 0 9 4 270.7 ftz 0.23 0.01 0 <br /> 6 W=>S Garage Frame-Wood Main 13 2 0 9 4 18.7 ftz 0.23 0.01 0 <br /> 7 E=>N Garage Frame-Wood Main 13 11 2 9 4 104.2 ftz 0.23 0.01 0 <br /> DOORS <br /> # Ornt Door Type Space Storms U-Value Ft In <br /> In Ft eightln Area <br /> 1 N=>W Insulated Main None .4 3 8 24 ftz <br /> 2 N=>W Wood Main None .46 2 8 8 21.3 ftz <br /> WINDOWS <br /> Orientation shown is the entered orientation => chan ed to As Built rotated 270 degrees). <br /> Wall Overhang <br /> # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening <br /> 1 N=>W 1 Vinyl Low-E Double Yes 0.34 0.31 N 30.0 ftz 1 ft 0 in 1 ft 0 in None Exterior 5 <br /> 2 E=>N 2 Vinyl Low-E Double Yes 0.34 0.31 N 45.0 ftz 1 ft 0 in Oft 11 in None Exterior 5 <br /> 3 E=>N 2 Vinyl Low-E Double Yes 0.34 0.31 N 18.0 ftz 1 ft 0 in Oft 11 in None Exterior 5 <br /> 4 S=>E 3 Vinyl Low-E Double Yes 0.34 0.31 N 45.0 ftz 1 ft 0 in Oft 11 in None Exterior 5 <br /> 5 S=>E 3 Vinyl Low-E Double Yes 0.34 0.31 N 22.5 ftz 1 ft 0 in Oft 11 in None Exterior 5 <br /> 6 S=>E 3 Metal Low-E Double Yes 0.55 0.34 N 72.0 ftz 10 ft 0 in 0 ft 2 in None Exterior 5 <br /> 7 W=>S 4 Vinyl Low-E Double Yes 0.34 0.31 N 22.5 ftz 19 ft 4 in 0 ft 2 in None Exterior 5 <br /> 8 W=>S 4 Vinyl Low-E Double Yes 0.34 0.31 N 75.0 ftz 1 ft 0 in 0 ft 11 in None Exterior 5 <br /> GARAGE <br /> # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation <br /> 1 619.13 ftz 619.13 ftz 62.2 ft 9.3 ft 0 <br /> INFILTRATION <br /> # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 <br /> 1 Wholehouse Proposed ACH(50) .000413 3077.1 168.82 316.93 .1418 7 <br /> HEATING SYSTEM <br /> # System Type Subtype Speed Efficiency Capacity Block Ducts <br /> 1 Electric Heat Pump/ None Singl HSPF:8.5 42 kBtu/hr 1 sys#1 <br /> 2/8/2021 1:02 PM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 3 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.