Laserfiche WebLink
D <br /> i <br /> re <br /> t <br /> • <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. F.F.E. shall be a minimum of 8"above the road elevation and an engineered site plan. <br /> 2: Lots shall be graded to comply with R401:3 of the F.B.C. <br /> 3: . Compaction test required if 24"or more of fill.dirt is brought in at any.one place. <br /> 4: Tie in survey required before pouring-concrete. <br /> 5; .Driveways require.a R.O.W. use permit: All 4 sides of driveway thra the sidewalk shall have <br /> expansion material.: <br /> 6: All setbacks shall be met. <br /> -7 All property markers shall be uncovered.and marked at time:of first inspection. <br /> -8:- All A.D.A.requirements shall be met: <br /> 9. No electric,.plumbing;,mechanical, or framing shall be covered without an inspection.and <br /> approval first. - <br /> 10:All Garages shall.comply with section R302:6 of the F.B.C. (Fire Separation).: <br /> 1 L Appliances.shall not'b.e installed in a location where subject to mechanical damage-unless <br /> protected by approved barriers. M3034 of the F.B.0 <br /> 12. Water heaters shall comply with section P607.3 of-the F.B.C. <br /> 13. Foundation.supports for A/C units'.shall be raised at least 3" above finished grade. M l308;1' <br /> 14:.Return air in all bedrooms: F.B:C.. M1620.4 <br /> 15. Smoke detectors are to be.installed in accordance "with-R3111 of the F.B.C. <br /> 16:All glazing requirernents are to-be in:accordance with R308A of the F.B.C: <br /> 17. All means of egress are.to:be in accordance with R311 of the'F.B.0 <br /> 18. "Green gypsum board" shall riot be used as a backer in showers or tubs. R702-4.2 F.B.C. <br /> 10. Combination-type AFCI breakers are required at all locations requiririg an AFCI type breaker. <br /> 20. Carbon monoxide alarms will be required in new construction that.uses fossil-burning heating <br /> or appliances or an attached garage.' They shall_be installed in accordance with the F.B.C. <br /> .21. All plumbing, mechanical; and electrical shall he separate from unit to unit. This includes all <br /> underground plumbing'and electric. <br /> 22. All 2016 N.E.C. Codes will be enforced. <br />