Laserfiche WebLink
WIYdQOlN SYSTEMS <br /> 1900 SW 44TH AVE. <br /> OCALA,FLORIDA 34474 <br /> W W W.CW S.CC <br /> 3" PVC <br /> MULL BAR <br /> NON-IMPACT <br /> RETRO FIT "L"ANGLE MULL BAR CLIP <br /> MULL BAR CLIP TWO REQ'D PER EACH END OF MULL JQ Z .Q Z <br /> I- ❑WO U)W00 <br /> MULLBAR MULL BAR Z W J❑ Q - <br /> W ZOZ =ZW <br /> a. r <br /> LL z=2<wwoo <br /> I— �J I �-' O OHO < of <br /> INSTALLATION ANCHOR d INSTALLATION ANCHOR U =H <br /> SEE TABLE 1 I SEE TABLE 1 o Z rp Z Z P in a <br /> ADD STRUCTURAL ELEMENTS ADD STRUCTURAL ELEMENTS Z O O U S U- <br /> SEALANT ALONG SEALANTALONG Q Z Z <br /> OUTSIDE EXPOSED , AS REQ'D TO MAKE LEVEL FOR OUTSIDE EXPOSED J - AS REQ'D TO MAKE LEVEL FOR } -—LL 2 O O LL Z <br /> EDGE BY INSTALLER MULL BAR EDGE BY INSTALLER MULL BAR - of 2 g< Ix O H F-F Z— <br /> PERIMETER SEALANT O PERIMETER SEALANT I w O 0 v2 O w 9 W <br /> BYINSTALLER BY INSTALLER � Z w O w rn F <br /> li <br /> INSIDE AND OUT MIN.EMBEDMENT INSIDE AND OUT MIN.EMBEDMENT D. =o_ D:O—rn <br /> SEE TABLE 1 SEE TABLE 1 O =F. 0- <br /> of = <br /> a o w'aw Cn <br /> SUBSTRATE BY OTHERS SUBSTRATE BY OTHERS <br /> SEE TABLE 1 SEE TABLE 1 <br /> MIN.EDGE DIST. MIN.EDGE DIST. <br /> SEE TABLE 1 <br /> SEE TABLE 1 <br /> - <br /> D VERTICAL SECTION �E1 VERTICAL SECTION �\`JCpSA.IIJ4 JJ�� <br /> 9 TYPICAL FLANGE(RETRO FIT)ANCHORAGE 9 TYPICAL FLANGE("L"ANGLE)ANCHORAGE �� .GBN0`• �i� <br /> HEAD AND JAMBS SIMILAR FOR FLANGE INSTALLATION HEAD AND JAMBS SIMILAR FOR FLANGE INSTALLATION <br /> zz"o No,58201 �c <br /> Ex * w= <br /> till till <br /> 08/06/2020 <br /> NOTES: <br /> LUCAS A.TURNER,P.E.. <br /> TABLE 1:APPROVED MULL CLIP INSTALLATION FASTENERS 1.BOX FRAME MULL INSTALLATION SIMILAR TO FLANGE FRAME. FL PE#58201 <br /> 2428 Old Natchez Trc Trl <br /> SUBSTRATE TYPE ANCHOR TYPE MIN.EMBEDMENT MIN.EDGE DIST. 2.SILL STOOL MUST BE FLUSH AGAINST INSIDE OF MULLED WINDOWS Camden,TN 38320 <br /> CONCRETE.(2.0 KSI MIN.) 3/16"ITV TAPCON 1" 3" AFTER INSTALLATION. PH.941-380-1574 <br /> CONCRETE(2.85 KSI MIN.) 3/16"ELCO ULTRACON 1-314" 1" 3.RECESS RETRO MULLION CLIP 3/8"MAX.FOR CLEARANCE OF WINDOW SHEET DESCRIPTION: <br /> HOLLOW or GROUT-FILLED CMU(ASTM C-90) 1/4"ELCO ULTRACON 1-114" 2-1/2" UNIT AS NEEDED. INSTALLATION DETAILS <br /> 3116"ITW TAPCON 4.FOUR4( FLANGE <br /> OR ELCO ULTRACON <br /> 2XMIN.SOUTHERN PINE(G=0.55) 1-3/8" 7/8" DRAWN BY: DATE: <br /> )ANCHORS REQUIRED PER"T"MULL CLIP,SEE SHEET 2. <br /> 2XMIN.SOUTHERN PINE(G=0.55) #10 WOOD SCREW 1-3/8" 7/8" TWO(2)or THREE(3)ANCHORS REQUIRED PER"L"MULL CLIP,SEE SHEETS 2-3. <br /> IRS 04/13/09 <br /> 16 GAUGE(0.060")MIN.STEEL STUD #10-16 HILTI KWIK-FLEXOR ITW FULL THREAD 7/16" 5.SEAT MULLION TIGHT TO MULL CLIP. DWG#: Rev.: <br /> (33 KSI YIELD MIN) TEKS SELF-DRILLING SCREW THRU 0.060"' CWS 430 D <br /> 1/8"ALUM.(6063-T5 MIN.)OR #10 GRADE 5 SELF-TAPPING/ FULL THREAD 6.FOR ANCHORAGE DETAILS FOR THE WINDOW,REFER TO THE WINDOW <br /> 11W STEEL(33 KSI MIN.) DRILLING SCREW THRU 0.125" 7/16" SPECIFIC INSTALLATION DETAILS. SCALE: SHEET <br /> 1:2 9 OF 10 <br />