Daniel W. Dunzik Architect LEED-AP <br /> 370 Burnt Hill Rd.Skillman NJ.08558 908-872-3664 <br /> StudioGdesign@comcast.net February 24,2021 <br /> Re:Proposed Photovoltaic Solar Panel Installation <br /> William Bryk <br /> 6777 WAGON TRAIL ST <br /> ZEPHYRHIILS,FL 33541 <br /> Dear Plan Reviewer: <br /> Certification:I have reviewed the engineering testing reports for the racking and attachments to be used on this project <br /> and I certify that the products are capable of supporting the code required loads and are suitable for this installation <br /> when installed in strict compliance with the manufacturers printed instructions. <br /> Regarding the solar panel array installation on the above referenced project please note that an inspection was <br /> performed by a representative of the Architect/Engineer of Record,and analysis of the existing structure was <br /> conducted.There is adequate structural capacity for the installation of the array with the following recommendations: <br /> 1.The array will be installed on the existing roof.The roof framing is constructed of 2"x4"wood trusses @24"o.c. <br /> spanning 207'with a top chord length of 23'with intermediate supports at 1/3rd points,making the effective longest <br /> span equals 79" with 1/2"plywood sheathing.The new array(See Site map by contractor)will add 2.63 Lb./Sff, <br /> overall to the roof.No additional structural support is required for the roof structure. <br /> 2.The attachment system shall be secured to the roof and shall be in strict compliance with manufacturers printed <br /> instructions.The attachment system shall be UL 1703 approved tested.Provide 6 mil.vapor barrier between dissimilar <br /> metals.Provide water tight gasket and sealant at all penetrations. Attachments shall follow panel rows as specified by <br /> the system manufacturer's installation manual.The panel angle shall match the roof slope.Reference summary table <br /> below: <br /> Roof Type: Shingle Fastener Max Spacing(in.) <br /> Attachment System: "Ecofasten Solar""Rock-IT'® Wind Zone 1 Wind Zone 2 Wind Zone 3 <br /> Fastener Info: min.5/16"x 4"long stainless-steel lags with a min. 48 32 32 <br /> embedment of 3"into the rafters <br /> 3.Solar Modules shall be UL-1703 rated.Refer to manufacturers specifications sheets. <br /> 4.Positive drainage of the system shall be so as not to void the existing roof warranty. <br /> 5.All aspects of the installation shall comply with the Florida Administrative Code,2020 Florida Building Code- <br /> Residential Seventh Edition,ASCE-7-16,2020 Florida Building Code—Energy Conservation,Seventh Edition,2017 <br /> National Electric Code,All Local Governing County and Municipal Ordinances adopted by reference or enacted by <br /> law.All components used meet the criteria of the Florida Solar Energy Center. <br /> 6.Please refer to the attached structural calculations. <br /> If you have any questions relating to this matter,please contact me at your earliest convenience.Thank you. <br /> OF ..to <br /> CO <br /> • L W. <br /> Daniel W.Dunzik,RA.LEED-AP 4 .• <br /> FL.Lic.No.AR98795 •. A 987 5 <br />