My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
21-1608
Zephyrhills
>
Building Department
>
Permits
>
2021
>
21-1608
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/9/2022 11:26:43 AM
Creation date
5/9/2022 11:26:32 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
21-1608
Building Department - Name
KING,REGINA
Address
39028 6TH AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
54
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ONEMO etc. <br /> ONEMOletc. <br /> TABLE 1:RoLL-GooDS iron MODIFIED BITUMEN ROOF SYSTEMS 5.7.2 For mechanically attached components or partially-bonded insulation,the maximum design pressure for the <br /> Type product - Material Standard plants) selected assembly shall meet or exceed at least the Zone 1 PRIME design pressure determined in accordance with <br /> Reference Type Grade FBC Chapter 16. Elevated pressure zones shall employ an attachment density designed by a qualified design <br /> Ruberold•HW Granule ASTM D6164 I G GA professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WDS,FM Loss <br /> Ruberold•HW Granule FR ASTM D6164 I G GA Prevention Data Sheet 1-29,Roofing Application Standard RAS 127 and Roofing Application Standard RAS 137. <br /> SBS,Granule- Ruberold•Mop Plus Granule FR ASTM D6164 If G GA Assemblies marked with an asterisk'carry the limitations set forth in Section 2.2.10.2 of FM Loss Prevention Data <br /> Surface Ruberold°Mop Plus Granule ASTM D6164 II G GA Sheet 1-29(February 2020)for Zone 2/3 enhancements. <br /> Membranes Ruberold°EnergyCap^Mop Plus Granule FR ASTM D6164 II G CA-S 5.7.3 For assemblies with all components fully bonded in place,the maximum design pressure for the selected assembly <br /> Ruberoid•HW Plus Granule ASTM D6164 II G GA <br /> Ruberoid°HW Plus Granule FR ASTM D6164 II G GA shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16.No rational analysis <br /> Ruberold•Ener Ca"'HW Plus Granule FR ASTM D6164 II G CA-5 is permitted for these systems. <br /> 5.8 All components in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 61G20-3. <br /> Refer to the Product Approval of the component manufacturer for components listed in Appendix 1 that are <br /> 5.1 This is a Building Code Evaluation.Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer produced by a Product Manufacturer other than the report holder on Page 1 of this Evaluation Report. <br /> of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting <br /> or design guidance unless retained specifically for that purpose. <br /> ord <br /> 5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions(i.e.,Broward and Miami- GAF Modified Bitumen Roof Systems shall be Installed in acc ance with GAF published installation Instructions, <br /> Dade Counties). subject to the Limitations/Conditions of Use noted herein. <br /> 5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in <br /> accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this <br /> 5.4 This Evaluation Report does not Include evaluation of fire classification. Refer to FBC 1505 for requirements and product. <br /> limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations <br /> concerning the use of foam plastic insulation. <br /> 5.5 This Evaluation Report does not Include evaluation of roof edge termination.Refer to FBC 1504.5 for requirements Contact the named CIA entity for manufacturing facilities covered by F.A.C.Rule 61G20-3 CIA requirements.Referto Section 4 herein for products and production locations having met codified material standards. <br /> and limitations regarding edge securement for low-slope roofs. <br /> 5.6 Refer to FBC 1512 for requirements and limitations regarding recover Installations. QUALITY,ASSURANCE ENTITY: <br /> 5.6.1 For mechanically attached components over existing roof decks,fasteners shall be tested In the existing deck for UL,LLC—QUA9625:(414)248-6409,karen.buchmann@ul.com <br /> withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum THE 9I-PAGES THAT FOLLOW FORM PARTOF THIS EVALUATION REPORT- <br /> requirements for the system.Testing shall he in accordance with ANSI/SPRI FX-1 or Testing Application Standard <br /> TAS 105. <br /> 5.6.2 For bonded insulation or membrane over existing substrates in a re-roof(tear off)or recover installation,the <br /> existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed.If any <br /> surface conditions exist that bring system performance Into question,field uplift testing in accordance with <br /> ANSI/SPRI IA-1,ASTM E907,FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124 shall <br /> be conducted on mock-ups of the proposed new roof assembly. <br /> 5.6.3 For bonded insulation or membrane over existing substrates in a recover installation,the existing roof system shall <br /> be capable of resisting project design pressures on Its own merit to the satisfaction of the Authority Having <br /> Jurisdiction,as documented through field uplift testing In accordance with ASTM E907,FM Loss Prevention Data <br /> Sheet 1-52 or Testing Application Standard TAS 124. <br /> 5.7 Refer to Appendix 1 for system attachment requirements for wind load resistance. <br /> 5.7.1 "MDP"=Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, <br /> and reflects the ultimate passing pressure divided by 2(the 2 to 1 margin of safety per FBC 1504.9 has already <br /> been applied).Refer to FBC 1609 for determination of design wind loads. <br /> NEMO ETC,LLC Evaluation Report 01506.IL04-R39 NEMO ETC,LLC Evaluation Report 01506.11.04-1129 <br /> &Aifimtrc/A,UMfUotlon M3ZISS 71nEDITION(2020)FRC NON-HVHZ EVALUATION FL5680-R29 cen(,mteof`A,th,,kuon p324SS 7-'EDITION(29201 FBC NON-HVHZ EVALUATION FL568DR29 <br /> GAF Modified Bitumen Roof Systems Revision 29:10/11/2020 GAF Modified Bitumen Roof Systems Revision 29:10/21/2020 <br /> Page 5 of 6 page 6 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.