Laserfiche WebLink
COMcheck Software Version 4.1.5.1 <br /> Mechanical Compliance Certificate <br /> Project Information <br /> Energy Code: 2017 Florida Building Code, Energy Conservation <br /> Project Title: Zephyrhills <br /> Location: Zephyrhills, Florida <br /> Climate Zone: 2a <br /> Project Type: New Construction <br /> Construction Site: Owner/Agent: Designer/Contractor: <br /> XXX Gall Blvd. Chipotle Mexican Grill, INC. Joe Jones <br /> Zephyrhills, FL 33541 PO Box 182566 National Engineering <br /> Columbus, OH 43218 4635 Trueman Blvd. <br /> 614-318-2400 Suite 250 <br /> Hilliard, OH 43026 <br /> Additional Efficiency Package(s) 614-328-2024 <br /> jjones@nationalengineering.com <br /> Reduced interior lighting power. Requirements are implicitly enforced within interior lighting allowance calculations. <br /> Mechanical Systems List <br /> Quantity System Type&Description <br /> 1 RTU-1 (Single Zone): <br /> Heating:1 each-Duct Furnace,Gas,Capacity=180 kBtu/h <br /> Proposed Efficiency=80.00%Ec,Required Efficiency: 80.00%Ec <br /> Cooling:1 each-Single Package DX Unit,Capacity=118 kBtu/h,Air-Cooled Condenser,Air Economizer <br /> Proposed Efficiency=11.00 EER, Required Efficiency: 11.00 EER +12.6 IEER <br /> Fan System: FAN SYSTEM 1 --Compliance(Motor nameplate HP method) :Passes <br /> Fans: <br /> RTU1 Supply,Constant Volume,3600 CFM,2.0 motor nameplate hp,0.0 fan efficiency grade <br /> 1 RTU-2(Single Zone): <br /> Heating:1 each-Duct Furnace,Gas,Capacity=180 kBtu/h <br /> Proposed Efficiency=80.00%Ec, Required Efficiency: 80.00%Ec <br /> Cooling:1 each-Single Package DX Unit,Capacity=122 kBtu/h,Air-Cooled Condenser,Air Economizer <br /> Proposed Efficiency=11.00 EER, Required Efficiency: 11.00 EER +12.6 IEER <br /> Fan System: FAN SYSTEM 1 --Compliance(Motor nameplate HP method) :Passes <br /> Fans: <br /> RTU1 Supply,Constant Volume,3600 CFM,2.0 motor nameplate hp,0.0 fan efficiency grade <br /> 1 DWH-1: <br /> Gas Instantaneous Water Heater,Capacity:0 gallons,Input Rating:199 kBtu/h w/Circulation Pump <br /> Proposed Efficiency:0.62 EF, Required Efficiency:0.62 EF <br /> Mechanical Compliance Statement <br /> Compliance Statement. The proposed mechanical design represented in this document is consistent with the building plans, <br /> specifications, and other calculations submitted with this permit appli Nllfprpposed mechanical systems have been <br /> designed to meet the 2017 Florida Building Code, Energy Conservati eFF n OMcheck Version 4.1.5.1 and to comply <br /> with any applicable mandatory requirements listed in the 1 _✓0 <br /> Richard T.Jones, PE <br /> Name-Title Signatur6:. 8843 Date <br /> Project Title: Zephyrhills ®�•� �I� Report date: 01/14/21 <br /> 0. <br /> Data filename: U:\2020\2001004 Chipotle-Zephyrhills, FL\calciySt>�t�(S �Lck Page 3 of 17 <br /> �j�`/'/0®NIAL\\\\\� <br />