Laserfiche WebLink
Section <br /> # Final Inspection Complies? Comments/Assumptions <br /> & Req.ID <br /> C303.3, j Furnished 0&M instructions for ;❑Complies ;Requirement will be met. <br /> C408.2.5. !systems and equipment to the E❑Does Not <br /> 2 ;building owner or designated <br /> [F[17]3 ;representative. ;❑Not Observable <br /> ❑Not Applicable <br /> ! <br /> C303.3, ;Furnished O&M manuals for HVAC ;❑Complies ;Requirement will be met. <br /> C408.2.5. ;systems within 90 days of system ❑Does Not <br /> 3 ;acceptance. <br /> [F18]3 ! ;❑Not Observable <br /> ❑Not Applicable <br /> C403.2.4. ;Minimum one humidity control device ;❑Complies :Requirement will be met. <br /> 2.4 per installed UDoes Not <br /> [FI56]3 !humidification/dehumidification <br /> system. Controls prevent ;❑Not Observable <br /> isimultaneous operation of ;❑Not Applicable <br /> humidification and dehumidification <br /> ;equipment. ; <br /> C403.2.4. ;Minimum one humidity control device ;❑Complies !Requirement will be met. <br /> 2.4 per installed !❑Does Not <br /> [F]56]3 ;humidification/dehumidification ❑Not Observable <br /> system. Controls prevent <br /> 'simultaneous operation of ;❑Not Applicable <br /> humidification and dehumidification <br /> ;equipment. <br /> C403.2.1 HVAC systems and equipment design ;❑Complies ;Requirement will be met. <br /> [F]50]3 ;loads calculated in accordance with E❑Does Not <br /> !ANSI/ASHRAE/ACCA Standard 183 or 1 <br /> ;ACCA Manual N or by an approved ❑Not Observable <br /> equivalent computational procedure. !❑Not Applicable <br /> ;Design loads shall be attached to the <br /> code compliance form submitted to <br /> the building department when the ! <br /> ;building is permitted or, in the event ! <br /> {the mechanical permit is obtained at a <br /> later time,the sizing calculation shall <br /> be submitted with the application for <br /> ;the mechanical permit. <br /> C403.2.2 ;HVAC systems and equipment ;❑Complies ;Requirement will be met. <br /> [FI27]3 1 capacity does not exceed calculated �,❑Does Not <br /> loads. <br /> ❑Not Observable <br /> ❑Not Applicable <br /> C403.2.4. !Heating and cooling to each zone is ;❑Complies ;Requirement will be met. <br /> 1 )controlled by a thermostat control. !❑Does Not <br /> [FI47]3 ;Minimum one humidity control device <br /> per installed ;❑Not Observable <br /> humidification/dehumidification ❑Not Applicable <br /> system. <br /> C403.2.4. i Heating and cooling to each zone is ;❑Complies ;Requirement will be met. <br /> 1 controlled by a thermostat control. T❑Does Not <br /> [FI47]3 ;Minimum one humidity control device 1 <br /> per installed ;❑Not Observable <br /> {humidification/dehumidification ❑Not Applicable <br /> i system. <br /> C403.2.4. ;Thermostatic controls have a 5 °F ;❑Complies ;Requirement will be met. <br /> 1.2 Mdeadband. ;❑Does Not <br /> [F[38]3 <br /> ❑Not Observable <br /> } ;❑Not Applicable <br /> 11 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) <br /> Project Title: Zephyrhills Report date: 01/14/21 <br /> Data filename: U:\2020\2001004 Chipotle-Zephyrhills, FL\calcs\Zephyrhills,FL Comcheck.cck Page 13 of 17 <br />