CaptiveAire Systems,Inc. <br /> NOTICE OF ACCEPTANCE: EVIDENCE SUBWrTED <br /> 1. Evidence submitted under previous NOA's <br /> A. DRAWINGS "Submitted under NOA #14-0722.16" <br /> 1. Drawing No. EXHAUST, titled "Upblast/ Downblast/ Curb", sheets 1 through 12 of <br /> 12, dated 08/25/2008, with revision 5 dated 05/06/2015, prepared by CaptiveAire <br /> Systems, Inc, signed and sealed by L. David Rice, P.E. <br /> B. TESTS "Submitted under NOA #14-0722.16" <br /> 1. Test reports on Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 along <br /> with marked-up drawings and installation diagram of Centrifugal Upblast Roof <br /> Mounted Exhaust Fans (Model NCA36FA), prepared by Intertek/Architectural <br /> Testing, Inc., Test Report No. E6374.01-109-18, dated 04/16/2015, signed and sealed <br /> by Michael D. Stremmel,P.E. <br /> 2. Test reports on Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 along <br /> with marked-up drawings and installation diagram of Centrifugal Downblast Roof <br /> Mounted Exhaust Fans (Model DD36FA), prepared by Intertek/Architectural Testing, <br /> Inc., Test Report No. E6373.01-109-18, dated 04/16/2015, signed and sealed by <br /> Michael D. Stremmel,P.E. <br /> 3. Test reports on 1)Uniform Static Air Pressure Test,Loading per FBC TAS 202-94 <br /> 2)Large Missile Impact Test per FBC,TAS 201-94 <br /> 3) Cyclic Wind Pressure Loading per FBC,TAS 203-94 <br /> along with marked-up drawings and installation diagram of Motorized Exhaust Vent <br /> (Model DU10), prepared by Architectural Testing, Inc., Test Report No. E1562.01- <br /> 109-18, dated 11/13/2014, signed and sealed by Michael D. Stremmel, P.E. <br /> "Submitted under NOA#08-1124.09" <br /> 4. Test reports on 1)Uniform Static Air Pressure Test,Loading per FBC TAS 202-94 <br /> 2)Large Missile Impact Test per FBC,TAS 201-94 <br /> 3)Cyclic Wind Pressure Loading per FBC, TAS 203-94 <br /> along with marked-up drawings and installation diagram of Series/Model HRE-24, <br /> high velocity roof fan, BI-36CARM, roof mounted exhaust fan and A5-925, modular <br /> down discharge blower, prepared by Architectural Testing, Inc., Test Report No. <br /> 83747.01-109-18, dated 10/15/2008, with Revision 1 dated 01/06/2009, signed and <br /> sealed by Michael D. Stremmel,P.E. <br /> �g 07/ 19 <br /> Carlos 1VL Utrera,P.E. <br /> Product Control Examiner <br /> NOA No.19-0717.08 <br /> Expiration Date:March 4,2024 <br /> Approval Date:August 15,2019 <br /> E-1 <br />