Laserfiche WebLink
a son Hisrory <br /> Dimensional Data - Upblast Aluminum Fans Dercrl tlan Redredb E661 <br /> e DR Models oss 1 <br /> Incrrea3ed Design ressure r.15OFSP 717/14 <br /> _5 Added CurbHell; s <br /> PRODUCT REVISED 6 ChangedNotes On CurbN reffy <br /> as eomgplying 1 with the Florida ac ncro cs ou <br /> Buildin CCodda EF- o ern a ran o vramrM93 <br /> NOA-na• 19-0717.08 WIND PRESSURES FROM THE General Notes: <br /> Expiration e0310412024 STRUCTURAL DRAWINGS: <br /> By +11.0 / 25.0 1.This approval is for the structural capacity and impact rating of the exterior <br /> Mionalk-Datib Product Control housing only,it does not include any interior mechanisum or electrical part. <br /> 2.These fans have not been Wind tested for Wind Driven Rain Test per Florida <br /> W Building code,TAS 100(A)-95. <br /> FAN MODEL HT(in) W(in) C in) WEIGHT Ibs <br /> DU10 14-1/2 17-3/4 19 30 <br /> DU12 18 22 19 40 <br /> DU25 25-1/4 25-1/2 21 50 <br /> DU30 , 25-1/4 25-1/2 21 50 <br /> DU33 25-1/4 25-1/2 21 50 <br /> DU50 27-1/4 28-7/8 21 55® <br /> a DU75 30-1/2 31-7/9 24-3/4 60 Rlli <br /> DU85 30.1/2 31-7/9 24-3/4 60 105S&d eeek rJ <br /> HT DU180 33-3/4 39-3/8 28 190 uaamnurgg. 54217 <br /> Phone 921t(1 7 11142 <br /> DU200 33-3/4 38-7/8 28 195 Fes 92d�1-tray <br /> DU240 37-1/2 433/8 33 270 wmwwrme•mc wn <br /> Fantle Fla c.F-OIDMOO5081 <br /> DU300 40 52-3/4 40 410 Ceff=190t uarordstion#= <br /> nib <br /> DU360 45-9/16 63-7/16 44 470 Regaueuoed .SM <br /> NCA08 25-1/4 27-1/4 21 105 <br /> NCA10 27-1/4 30-1/4 21 120 <br /> NCA14 30-1/2 33-3/4 24-3/4 140 <br /> NCA16 33-3/4 39-3/8 28 190 <br /> C NCA18 33-3/4 38-7 8 28 195 y <br /> NCA24 37-1 2 433 8 33 270 No. HOW <br /> NCA30 1 40 1 52-3/4 40 410 — <br /> �4 <br /> DESIGN PRESSURE:+150.0/-1.... NCA36 45-9/16 63-7/16 44 470 PSF SEE PAGE 13 FOR ALTERNATE BRANDS 0P , <br /> ; ti <br /> LARGE MISSILE IMPACT RESISTANT ��°lAiliti;L�`'ti� <br /> Notes: JUN 0 B 2819 <br /> 1. Tested in accordance to Florida Building Code test protocol TAS-201,TAS-202,TAS203. CapfiveAtre, Inc.commercial kitchen ventilation <br /> 2. Tested for areas including high velocity hurricane zones. on 4647 Para Paris Road,Ralei9 h NC 27616 <br /> 3. Tested under Miami-Dade County Notification number AT]08033. 9 <br /> P 800.334.925(F 919.227.5994 <br /> Material: N A Part Number:N/A UnlessothemixeSpeclned <br /> Blank Size: A x MACOLA umber. Dlmmetonsarelnhches. wAN <br /> el t: N/A lbs Drowln B P <br /> Name:UPBLAST Standard Tolerances are: Air -N.� <br /> Drawn N e Fraclionr21l16 <br /> Dedmal:J(Xt.05 , , r <br /> Dravnn NUM er. X A STO )MI.015 <br /> Sheet:1 ot 13 ansles: stTHEPERFORMANCE COMPANY <br />