My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
21-1628
Zephyrhills
>
Building Department
>
Permits
>
2021
>
21-1628
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/9/2022 11:40:55 AM
Creation date
5/9/2022 11:40:52 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
21-1628
Building Department - Name
DITTMAN,KENNETH
Address
5740 DOGWOOD ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Force Engineering&Testing Inc. <br /> 19530 Ramblewood Drive <br /> Humble,TX 77338 <br /> Compliance Statement: The product as described in this report has demonstrated compliance with the <br /> Florida Building Code 2017,Sections 1504.3.2. <br /> Product Description: 1" Nailstrip Roof Panel,0.032"Aluminum, 15%" Coverage, Roof Panel attaching <br /> to 7/16" OSB or minimum 15/32" APA Plywood decking. Non-structural <br /> Application. <br /> Panel Material/Standards: Material: 0.032"3105-H24 ASTM B209 Aluminum conforming to Florida Building <br /> Code 2017 Section 1507.4.3. <br /> Corrosion Resistance:Panel Material shall comply with Florida Building Code <br /> 2017,Section 1507.4.3 <br /> Panel Dimension(s): Thickness: 0.032"Aluminum <br /> Width: 15%"max coverage <br /> Female Rib: 1"tall <br /> Male Rib: %"tall rib w/slotted strip. <br /> Panel Seam: Snap Lock <br /> Panel Fastener: Through Panel Slot:(1)#10-12 x 1"Pancake Type A <br /> %"minimum penetration through plywood <br /> Corrosion Resistance:Per Florida Building Code 2017,Section 1507.4.4. <br /> Panel Seam Sealant: 3/8"wide continuous bead of Titebond WeatherMaster Metal Roof Sealant <br /> applied to the inside edge of the male rib prior to installing the next panel. See <br /> detail for location. <br /> Substrate Description: Min.7/16"OSB sheathing or 15/32"thick,APA Rated plywood over supports at <br /> maximum 24"O.C. Design of OSB and plywood and supports are outside the <br /> scope of this evaluation. Substrate must be designed in accordance w/Florida <br /> Building Code 2017. <br /> C H k S <br /> STATE OF ;a► <br /> 00 0i O R 14' �4`♦. <br /> m orrnda. S. V <br /> r�cm I.-J, 1Ol+flll���,`♦, <br /> FL#4595.5 R4 August 14, 2017 <br />
The URL can be used to link to this page
Your browser does not support the video tag.