Laserfiche WebLink
ONEMO I etc. <br /> 5.6.1 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: <br /> The following wind uplift limitations apply to underlayment systems that are not prescriptively addressed in FRSA/TRI April <br /> 2012 (04-12) and are used in foam-on or mortar-set tile applications. Maximum Design Pressure is the result of testing for <br /> wind load resistance based on allowable wind loads and reflects the ultimate passing pressure divided by 2(the 2 to 1 margin <br /> of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012(04-12),Appendix A,Table 1A or FBC 1609 <br /> for determination of design wind loads. <br /> #1 Maximum Design Pressure=-52.5 psf: <br /> Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having <br /> Jurisdiction. <br /> Joints: Min.4-inch wide strips of Elastoflex SA-V over all OSB joints <br /> Base Ply: Polystick MTS Plus,self-adhered. <br /> Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick <br /> TU P or Polystick TU Plus,self-adhered. <br /> #2 Maximum Design Pressure=-90 psf: <br /> Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. <br /> Primer: None <br /> Base Ply: (Optional)Polystick MTS Plus,self-adhered. <br /> Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick <br /> TU P or Polystick TU Plus,self-adhered. <br /> #3 Maximum Design Pressure=-97.5 psf: <br /> Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. <br /> Primer: PG100 or ASTM D41 <br /> Base Ply: (Optional)Polystick MTS Plus,self-adhered. <br /> Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick <br /> TU P or Polystick TU Plus,self-adhered and back-nailed within the selvedge-edge side laps using 12 ga.x 1Y4"ring shank nails <br /> through 32 ga.,1-5/8"diameter tin caps spaced 12-inch o.c. <br /> #4 Maximum Design Pressure=-105 psf: <br /> Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. <br /> Primer: WB-3000 <br /> Base Ply: (Optional)Polystick MTS Plus,self-adhered. <br /> Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick <br /> TU P or Polystick TU Plus,self-adhered and back-nailed within the selvedge-edge side laps using 12 ga.x 1%"ring shank nails <br /> through 32 ga.,1-5/8"diameter tin caps spaced 12-inch o.c. <br /> #5 Maximum Design Pressure=-135 psf: <br /> Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. <br /> Primer: (Optional)PG100 or ASTM D41 <br /> Base Ply: (Optional)Polystick MTS Plus,self-adhered. <br /> Joints: Min.4-inch wide strips of Elastoflex SA-V over all plywood joints. <br /> Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick <br /> TU P or Polystick TU Plus,self-adhered. <br /> #6 Maximum Design Pressure=-315 psf: <br /> Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. <br /> Primer: PG100 or ASTM D41 <br /> Base Ply: (Optional)Polystick MTS Plus,self-adhered. <br /> Underlayment:HydraGuard Tile Pro, Mule-Hide SA-APP Cap Sheet, Mule-Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, <br /> Polystick TU Max,Polystick TU P or Polystick TU Plus,self-adhered. <br /> #7 Maximum Design Pressure=-622.5 psf: <br /> Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. <br /> Primer: PG100 or ASTM D41 <br /> Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. <br /> NEMO ETC,U.C. Evaluation Report P12060.02.09-R25 <br /> Certificate of Authorization#32455 6-EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-R29 <br /> Polyglass Roof Underlayments;(954)233-1230 Revision 25:10/14/2019 <br /> Page 6 of 16 <br />