C1 1 OWENS CORNING ROOFING AND ASPHALT LLC <br /> 1 1 K WeatherLock@ Underlayments(Non-HVHZ) <br /> TECHNICAL SERVICES, LLC <br /> PRODUCT DESCRIPTION AND LIMITS OF USE <br /> WeatherLock@ G WeatherLock@ G is an ASTM D 1970 self-adhered underlayment constructed from SBS <br /> (Brentwood, NH or modified asphalt, a fiberglass mat reinforcement and surfaced with granules. The <br /> Houston, TX) product is supplied in 2-sq. rolls with nominal dimensions of 3-ft x 66.7-ft. <br /> WeatherLock@ G is permitted to be used as prescribed in FBC Section 1507.1.1 and <br /> Table 1507.1.1.1 for mechanically attached roofing coverings. Exposure on the roof <br /> deck shall be limited to a maximum 30 days. <br /> WeatherLock@ Mat WeatherLock® Mat is an ASTM D 1970 self-adhered underlayment constructed from <br /> (Brentwood, NH or .SBS modified asphalt with a fiberglass mat.reinforcement. The product is supplied in is <br /> Houston, TX) 1-sq. rolls with nominal dimensions of 3-ft x 33.3-ft and 2 sq. rolls with nominal <br /> dimensions of 3-ft x 66JA <br /> WeatherLock@ Mat is permitted to be-used as prescribed in FBC Section 1507.1.1 and , <br /> Table 1507.1.1.1 for mechanically attached roof coverings. Exposure on the roof deck . <br /> shall be limited to a maximum 30 days. <br /> WeatherLock@ Metal WeatherLock@ Metal is an ASTM D 1970 self-adhered underlayment constructed from <br /> (Brentwood, NH) SBS modified asphalt with a fiberglass mat reinforcement and plastic film surface. The <br /> product is supplied in 2.0 sq.rolls with nominal dimensions of 3-ft x 66.7-ft. <br /> WeatherLock@ Metal is permitted to be used as prescribed in FBC Section 1507.1.1 and <br /> Table 1507.1.1.1 for mechanically attached roof coverings. Exposure on the roof deck <br /> shall be limited to a maximum 90 days. <br /> WeatherLock@ WeatherLock@ Specialty Tile & Metal (Green Facer) is an ASTM D 1970 nd FRSA/TRI <br /> Specialty Tile&Metal Florida High Wind Concrete and Clay Tile Installation Manual, Sixth Edition compliant <br /> (Green Facer) self-adhered underlayment constructed from SBS modified asphalt and surfaced with a <br /> (Brentwood, NH) non-woven polyester fabric. The product is supplied in 2.14 sq. rolls with nominal <br /> dimensions of 3-ft x 71.3-ft. <br /> WeatherLock@ Specialty Tile & Metal (Green Facer) is permitted to be used as <br /> prescribed in FBC Section 1507.1.1 and Table 1507.1.1.1. WeatherLock@ Specialty Tile <br /> & Metal (Green Facer)is permitted to be used with adhered clay or concrete tile roofing <br /> using Dupont TILE BOND Tr" Roof Tile Adhesive. Exposure on the roof deck shall be <br /> limited to a maximum 90 days. <br /> The maximum roof slope shall be 6:12 when used with clay or concrete tile installations <br /> without battens. Tile shall be stored on battens for roof slopes greater than 6:12. Tiles <br /> shall not be stacked greater 10 tiles per stack. <br /> WeatherLock@ WeatherLock@ Specialty Tile & Metal (Gray Facer) is an ASTM D 1970 and FRSA/TRI <br /> Specialty Tile&Metal Florida High Wind Concrete and Clay Tile Installation Manual, Sixth Edition compliant <br /> (Gray Facer) self-adhered underlayment constructed from SIBS modified asphalt and surfaced with a <br /> (Brentwood, NH) non-woven polyester fabric. The product is supplied in 2.14 sq. rolls with nominal <br /> dimensions of 3-ft x 71.3-ft. <br /> WeatherLock@ Specialty Tile&Metal (Gray Facer)is permitted to be used as prescribed <br /> in FBC Section 1507.1.1 and Table 1507.1.1.1. WeatherLock@ Specialty Tile & Metal <br /> (Gray Facer) is permitted to be used with adhered clay or concrete tile roofing using <br /> Dupont TILE BONDTm Roof Tile Adhesive or ICP Adhesive's Polyset RTA-1. Exposure <br /> on the roof deck shall be limited to a maximum 180 days. <br /> The maximum roof slope shall be 6:12 when used with clay or concrete tile installations <br /> without battens. Tile shall be stored on battens for roof slopes greater than 6:12. Tiles <br /> shall not be stacked greater 10 tiles per stack. <br /> OCR14002.11 a FL9777-R14 Page 2 of 4 <br /> This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK <br /> Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. <br /> This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not <br /> specifically addressed herein. <br />