My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
21-1630
Zephyrhills
>
Building Department
>
Permits
>
2021
>
21-1630
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/9/2022 11:43:10 AM
Creation date
5/9/2022 11:43:07 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
21-1630
Building Department - Name
OTERO,JUAN & ELSIE
Address
37420 CASTLEBERRY AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ONEMOletc. <br /> 5.6 Allowable Roof Covers: <br /> TABLE 1: ROOF COVER OPTIONS <br /> FBC Section: 1507.2 1507.3 1507.4&1507.5 1507.7 1507.8&1507.9 <br /> Clay and Concrete TILE Metal Wood <br /> Underlayment Asphalt slate orslate- <br /> y Shingles Mechanical Adhesive- Panels Shingles Type Shin les <br /> Attach Set g g Shingles Shakes <br /> Yes <br /> RhinoRoof®GRN Yes No No No No Yes <br /> (joint strips,1507.1.1.3/ <br /> R905.1.1.3) <br /> 5.7 Allowable Substrates: <br /> TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS <br /> Underlayment Application Substrates(designed to meet wind loads for project) <br /> Type Primer Material(s) <br /> RhinoRoof®GRN self-adhering Deck/sheathing None Plywood <br /> 5.8 Attachment Limitations: <br /> For use under mechanically attached NON-TILE prepared roof coverings, attachment shall be in accordance with <br /> the manufacturer's installation instructions, but—for mechanically attached underlayments or base sheets-not <br /> less than FBC 1507.1.1 or R905.1.1. <br /> 5.9 Exposure Limitations: <br /> TABLE 3: EXPOSURE LIMITATIONS <br /> Underlayment Prepared Roof Cover Installation Type Maximum Exposure(days) <br /> RhinoRoof®GRN Mechanically attached 30 <br /> 6. INSTALLATION: <br /> 6.1 RhinoRoof GRN shall be installed in accordance with Owens Corning Roofing and Asphalt, LLC published <br /> installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. <br /> 6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to <br /> remove any dust and debris prior to application,and prime the substrate(if applicable). <br /> 6.3 RhinoRoof®GRN: <br /> Shall be installed in compliance with requirements for an approved self-adhering underlayment(ASTM D1970)in <br /> FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering <br /> to be installed,and the manufacturer's installation instructions. <br /> BUILDING7. s <br /> As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this <br /> product. <br /> MANUFACTURI.NG PLANTS: <br /> Contact the named QA entity for manufacturing facilities covered by F.A.C.Rule 61G20-3 CIA requirements. Refer <br /> to Section 4 herein for products and production locations having met codified material standards. <br /> 9. QUALITY ASSURANCE ENTITY: <br /> PRI Construction Materials Technologies,LLC—QUA9110;(813)621-5777;bwilson@pricmt.com <br /> -END OF EVALUATION REPORT- <br /> NEMO ETC,LLC Evaluation Report 3m-OC-20-FBCER.01-R3 <br /> Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL32344-R1 <br /> Owens Corning RhinoRoof®GRN Revision 1:12/10/2020 <br /> Page 3 of 3 <br />