Laserfiche WebLink
a <br /> w <br /> I <br /> i <br /> i Single Family Dwelling <br /> Plan Review Comments <br /> 1. F.E.F: shall be a minimum of 8"above the road elevation and an engineered site plan. <br /> 2. Lots shall be graded to comply with R401.3 of the F.B.C. <br /> 3: Compaction test required if 24"or more of fill dirt is brow_ght in at any one place. <br /> 4; Tie in survey required before pouring concrete. <br /> 5: Driveways require.a R.O.W. use permit. All 4 sides of driveway thru the sidewalk shall have <br /> expansion material. <br /> 6: All setbacks shall be met. <br /> I. All property markeis shall be uncovered and marked at time of first inspection. <br /> 8: All A:D.A.'requirenients shall be met: <br /> 3; No electric,.plumbing, mechanical,or.framing shall be covered without an inspection and <br /> approval first. <br /> 10: All.Garages shall comply with section R302.6 of the F.B.C.-(Fire Separation).: <br /> l l.Appliances shall not be installed in a location where subject to mechanical damage unless <br /> protected by approved barriers. 1V1303,4 of the F,B.0 <br /> 12. water heaters-shall coinply with section P607.3 of the F:B.C: <br /> 13. Foundation supports for A/C units shall be raised at least 3"above finished grade. M1308A <br /> 14: Return air in all bedrooms. F.B.C. M1620.4 <br /> 15. Smoke detectors are to be installed in accordance_ with,R313:1 of the F.B.C. <br /> 16. All glazing reguirernents are to be in accordance with R30.8;4.of the F:B:C: <br /> 17. All means of egress are to be -in accordance with:R311 of the F.B.C. <br /> 18. "Green gypsum-board"shall not be used as a backer in showers or tubs. R702.4.2 F.B;C. <br /> 19. Combination-type AFCI breakers are required at all locations requiring an AFCI.type breaker <br /> 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning Beating. <br /> or appliances or an attached garage. They shall be installed in accordance with the F B.C. <br /> 21. All plumbing,mechanical, and electrical shall be separate from unit to unit: This includes all <br /> underground plumbing and electric. <br /> 22. All 2016 N:E.C. Codes will be enforced. <br />