Laserfiche WebLink
23. Tamper-Resistant Receptacles in accordance with 406.11 ofthe 2016 N..E.0 <br /> 24. In accordance with the Land Development Code, lots.shall.be sodded'before final at leas_t 10 <br /> feet around the structure. <br /> 25. R403.5.3Hot.water.pipe insulation. <br /> Insulation for hot water pipe with a minimum thermal resistance (R-value) of R-3 shall be applied to the <br /> following: . <br /> Piping�1,inch'(1,9.1 mm) and larger in.nominal diameter. . <br /> Piping,serving more than one dwelling unit. <br /> Piping located outside the conditioned space.. <br /> Piping from the:water heater to a distribution manifold: <br /> Piping.located under.a floor slab.- <br /> Buried in piping. <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25. Blower:door test shall be provided before C.O: <br /> 26.A copy of the enemy=cacls shall be ivith permit at all limes <br /> 27. Copt/of Fnal insulation reO6it shaff be provided with permit before fnaL <br /> 28. No fence,pool or screen enclosure :is issued with:this permit. <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C--Florida Building Code.6 h Edition <br /> R.O.W.-Right of Way. <br /> A.D.A.-Americans with Disabilities Act. N.E.C.-National Electric.Code (2016) <br />