Laserfiche WebLink
23. Tamper-Resistant Receptacles in accordance with 406.11 of the 2016 N.E.0 <br /> 24. In accordance with the Land Development Code,lots shall.be sodded before final at least 10. <br /> feet around the stricture: <br /> .25-. R403.5.3Hot water pipe insulation.' <br /> Insulation for hot.water'pipe with.a minimum thermal resistance (R-value) of R-3.sliall be applied to the: <br /> following: <br /> Piping./: inch (19:1 mm)and larger in nominal diameter._ <br /> Piping serving more than one dwelling unit. <br /> Piping located outside'the conditioned space. <br /> Piping from the.water heater to.a-distribution manifold:_ <br /> Piping.located under a.floor slab. <br /> Buried in piping. <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25: Blower.door test shall be provided before C.O. <br /> 26.A copy ofthe-enemy cacls shall be with permit at all times <br /> 27. Copu of Fnal'insulation:report shall be provided with permit before rnab <br /> 28.No fence, pool or screen enclosure :is issued with:this-pern:i <br /> F.F.E.-Finished Floor Elevation <br /> F.B.G.-Florida Building Code 6t'Edition <br /> R.O.W. Right of Way <br /> A.D.A.-Americans with Disabilities Act. N.E.C.=National Electric Code(2016) . <br />