Laserfiche WebLink
23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2016 N.E.0 <br /> 24. In accordance with the Land Develop_ merit Code, lots shall.be sodded before final at least 10 <br /> feet around the structure. <br /> 25. R403.5.3Hot water'pipe insulation <br /> Insulation for hot water pipe with a minimum thermal resistance (-R-value) of R-3 shall be applied to the <br /> following: <br /> Piping 3j, inch (19.1 mm)and larger in:nominal diameter..Piping,serving more than.one dwelling unit. <br /> Piping located outside the conditioned space. <br /> Piping from the water heater to a distribution manifold. <br /> Piping located under a floor slab.. <br /> Buried in piping, <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25. Blower door-test shall be provided before C.O. <br /> 26. A copy of the enerz.v cacls-shall be with perrntit at all times <br /> 27. Copy of final'insulation report shall de provided with permit before fnab <br /> 28.No fence,pool onscreen enclosure :is issued Ivith This perfnit <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C-Florida Building Code 6th Edition <br /> R.O.W:-Right of Way <br /> A.D.A.-.Americans with Disabilities Act N.E.C.-National Electric Code (2016) <br />