My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
21-1655
Zephyrhills
>
Building Department
>
Permits
>
2021
>
21-1655
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/9/2022 12:02:00 PM
Creation date
5/9/2022 12:01:59 PM
Metadata
Fields
Template:
Building Department
Company Name
DR HORTON INC
Building Department - Doc Type
Permit
Permit #
21-1655
Building Department - Name
DR HORTON INC
Address
7128 STEER BLADE DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
s <br /> D <br /> Q <br /> i <br /> i <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. F.F.E..shall be a minimum of 8" above the road elevation and an engineered site.plan. <br /> 2. Lots shall be graded to comply with R401.3 of the F.B.C. <br /> 3. Compaction test required if 24" or more of fill dirt is brought in at any one place. <br /> 4. Tie in survey required before pouring concrete. <br /> 5. Driveways require a R.O.W. use permit. All 4 sides of driveway thru the sidewalk shall have <br /> expansion material. <br /> 6: All setbacks shall be met. <br /> 7: All property markers shall be uncovered and marked at time of first inspection. <br /> 8: All A.D.A. requirements shall be met: <br /> R. No electric,plumbing;mechanical, or framing shall be covered without an inspection.and <br /> approval first. <br /> 10. All Garages shall comply.with section R302.6 of the F.B:C. (Fire—¶tion): <br /> 11. Appliances shall not be installed in a location.where.subject to in damage unless <br /> protected by approved barriers. M303.A of the FAC <br /> 12. Water heaters shall comply with section P607.3 of the F.B.C.- <br /> 13. Foundation supports.for A/C units-shall be raised at least 3" above finished grade. M 1308.1 <br /> 14. Return air in all bedrooms. F.B.C. M1620.4 <br /> 15. Smoke detectors are to be installed in accordance with R313-.1 of the F.B.C. <br /> 16. All glazing requirements are to be.in accordance with R308A of the F.B.C: <br /> 17. All means of egress are to be in accordance with R311 of the F.B.C. <br /> 18. "Green gypsum board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. <br /> 10. Combination-type AMbreakers are required at all locations requiring an AM type breaker <br /> 20. Carbon monoxide alarms will be required in new construction that.uses fossil-burning heating <br /> or appliances or an attached garage. They shall be installed in accordance with the F.B.C: <br /> 21. All plumbing,mechanical,and electrical shall be separate from unit to unit.. This includes_ all <br /> underground plumbing and electric. <br /> 22. All 2016 N.E.C. Codes will be enforced. <br />
The URL can be used to link to this page
Your browser does not support the video tag.