Laserfiche WebLink
- - Project Summary ry Job: R0221105 <br /> wrightsoft, Date: Feb 26,2021 <br /> Entire House By. AE <br /> Butterfleld Investments Inc Plan: Zephyrhills <br /> 31325 Ambedea Rd,Dade ON FL 33523 <br /> Project Information <br /> For: <br /> 3855013th fit,Zephyrhills,FL 33542 <br /> Notes: Load calculation was obtained from a digital copy of the CAD drawing. <br /> Design Information <br /> I <br /> Weather: Orlando Sanford,FL,US <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 41 OF Outside db 93 OF <br /> Inside db 70 OF Inside db 75 OF <br /> Design TD 29 OF Design TD 18 OF <br /> Daily range M <br /> Relative humidity 50 % <br /> Moisture difference 39 gr/Ib <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 17562 Btuh Structure 13155 Btuh <br /> Ducts 2013 Btuh Ducts 5234 Btuh <br /> Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh <br /> none <br /> (none) <br /> Humidification 0 Btuh Blower 3072 Btuh <br /> Piping 0 Btuh <br /> Equipment load 19575 Btuh Use manufacturer's data y <br /> Rate/swin multiplier 1.00 <br /> Infiltration Equipment sensible load 21461 Btuh <br /> Method Simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Average, <br /> Fireplaces 01 Structure 3098 Btuh <br /> Ducts 740 Btuh <br /> Central vent(0 cfm) 0 Btuh <br /> He tin coolingg� (none) <br /> Area(fF) 1567 1567 Equipment latent load 3838 Btuh <br /> Volume(ft3) 12534 12534! <br /> Airchanges/hour 0.38 0.20: Eq u ipment Total Load(Sen+Lat) 25299 Btuh <br /> Equiv.AVF(cfm) 79 42: Req.total capacity at 0.78 SHR 2.3 ton <br /> Heating Equipment Summary Cooling Equipment Summary <br /> Make 2.5 Ton-Franklin Make 2.5 Ton-Franklin <br /> Trade Split HP Trade Split HP <br /> Model GSZ140301 W Cond GSZ140301 W <br /> AHRI ref 201642087 Coil ARUF31614A` <br /> AHRI ref 201642087 <br /> Efficiency 8.2 HSPF Efficiency 12.0 EER,14 SEER <br /> Heating input Sensible cooling 21840 Btuh <br /> Heating output 27800 Btuh @ 47°F Latent cooling 6160 Btuh <br /> Temperature rise 0 OF Total cooling 28000 Btuh <br /> Actual airflow 0 cfin Actual airflow 933 cfm- <br /> Air flow factor 0 cfmBtuh Airflowfactor 0.051 cfmBtuh <br /> Static pressure 0.50 in H2O Static pressure 0.50 in H2O <br /> Space thermostat Load sensible heat ratio 0.85 <br /> Capacity balance point=33 OF <br /> Backup:Aux.Heat <br /> Input=8 kW, Output=27297 Btuh,100 AFUE <br /> Calculations approved byACCAto meet all requirements of Manual J 8th Ed. <br /> wrightsOft` 2021-Mar-02 09:47:46 <br /> •M •o - -,m Riglt-Sute®Urrversal2021 21.0.02 RSU07440 Page 1 <br /> ...iBUterfield-3855013thSt-LE\R0221104.nQ calc=W8 House Frortfaces:N <br />