Laserfiche WebLink
23. Tamper-Resistant Receptacles in accordance with 406.11 of the 2016 N.E:C <br /> 24. In accordance with the Land Develop_meat Code,lots shall be sodded before final at least 10 <br /> feet around the structure. <br /> 25: R403.5.3Hot water pipe insulation. <br /> Insulation for hot water pipe with a minimum thermal resistance (R-value) of R-3.shall be applied to the <br /> following: <br /> Piping.31,inch (19.1 mm)and largerin.nominal diameter. <br /> Piping serving more than:one dwelling unit. <br /> Piping located outside the conditioned space. <br /> Piping from the water heater to a-distribution manifold: <br /> Piping located under a floor slab: <br /> Buried in piping. <br /> Supply and return piping in recirculation systems other than demand recirculation-systems. <br /> 25. Blower,door test shall be provided before C.O: <br /> 26.A copy of the energy eacls shall be with perniit at all times <br /> 27. Copt/ofrinalinsulation report-shall be provided with permit before Linal <br /> 28. No fence,pool or screen-enclosure Is issued with ahis yermit <br /> RRE:-Finished Floor Elevation <br /> F.B.C- Florida Building Code 6t'Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act . N.E.C.-National Electric Code (2016) <br />