Laserfiche WebLink
23. Tamper-Resistant Receptacles in accordance with 406.11 of the 2016 N.E.0 <br /> 24. In accordance with the Land_ Development Code, lots shall be sodded before final at leas_t 10 <br /> feet around the structure. <br /> 25-..14403.5.Mot water pipe insulation <br /> Insulation for hot water pipe with a minimum thermal resistance (R-value) of R-3 shall be applied to the <br /> foilowing: <br /> Piping 31, inch (19.1 mm)and larger in nominal diameter._ <br /> Piping serving more than.one dwelling unit. <br /> Piping located outside the conditioned space. <br /> Piping from the water heater to a-distribution manifold:, <br /> Piping located under a floor slab. <br /> Buried in piping. <br /> 'Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25.Blower.door test shall be provided before C.O. <br /> 26.A cony of the energy cacis shall be with pernut at all times. <br /> 27. Copu of final.insulation report shall be provided ivith permit before flnaL <br /> 28. No fence,pool or -enclosure Is-issued with this permit <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C- Florida Building Code 6t'Edition <br /> R.O.W.--Right of Way <br /> A.D:A.-Americans with Disabilities Act N.E.C.-National Electric Code(2016) <br />