Laserfiche WebLink
FORM R405-2020 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: R0221105 Builder Name: "4js <br /> Street: 38552 13th,Sf Are Permit Office: City of Zephyrhills <br /> City,State,Zip: Zephyrhills,FL,33542 Permit Number: 16 T5 <br /> Owner: Jurisdiction: 611600 <br /> Design Location: FL,Orlando County: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 10. Wall Type�1504.0 sqft.) Insulation Area <br /> 2. Single family or multiple family Detached a.Concrete Block-Ext Insul, Exterior R=5.0 1210.70 ft2 <br /> b.Frame-Wood,Adjacent R=13.0 293.33 ft2 <br /> 3. Number of units,if multiple family 1 c.N/A R= ft2 <br /> 4. Number of Bedrooms 3 d.N/A R= ft2 <br /> 5. Is this a worst case? No 11.Ceiling Types (1567.0 sqft.) Insulation Area <br /> a.Under Attic(Vented) R=30.0 1567.00 ft2 <br /> 6. Conditioned floor area above grade(ft2) 1567 b.N/A R= ft2 <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 <br /> 7. Windows(181.5 sqft.) Description Area 12.Ducts R ft2 <br /> a. U-Factor: Dbl,U=0.65 181.51 ft2 a.Sup:Attic,Ret:Garage,AH:Garage 6 175 <br /> SHGC: SHGC=0.35 <br /> b. U-Factor: N/A ft2 13.Cooling systems kBtu/hr Efficiency <br /> SHGC: a.Central Unit 27.8 SEER:14.00 <br /> c. U-Factor: N/A ft2 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.679 ft. 14.Heating systems kBtu/hr Efficiency <br /> Area Weighted Average SHGC: 0.350 a.Electric Heat Pump 27.8 HSPF:8.20 <br /> 8. Skylights Area <br /> c. U-Factor:(AVG) N/A ft2 15.Hot water systems <br /> SHGC(AVG): N/A a.Electric Cap:40 gallons <br /> 9. Floor Types (1567.0 sqft.) Insulation Area EF:0.970 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1567.00 ft2 b. Conservation features <br /> b.N/A R= ft2 None <br /> c.N/A R= ft2 16.Credits CF <br /> Glass/Floor Area: 0.116 Total Proposed Modified Loads: 40.64 PASS <br /> Total Baseline Loads: 43.38 <br /> I hereby certify that the plans and specifications covered by Review of the plans and Q�TE <br /> this calculation are in compliance with the Florida Energy specifications covered by this i, _ p <br /> Code. calculation indicates compliance ��ii,,�r�c':� ,a� •� <br /> with the Florida Energy Code. F+ 1lrul '�." ;�;;.•���;t0 <br /> PREPARED BY: Before construction is completedzl <br /> DATE: 03-2-2021 this building will be inspected for I <br /> compliance with Section 553.908 * r, <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. <br /> with the Florida Energy Co vo <br /> �''Ob W�ET�O <br /> OWNER/AG EN BUILDING OFFICI t� I,///--A - <br /> DATE: DATE: wf <br /> v . <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.3.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an <br /> envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). <br /> 3/2/2021 10:14 AM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 4 <br />