Laserfiche WebLink
RESIDENTIAL SWIMMING POOL, SPA, AND/OR HOT TUB SAFETY ACT <br /> NOTICE OF REQUIREMENTS <br /> j <br /> I (We) acknowledge hat a new swimming pool, spa, or hot tub will be constructed or installed at (please print street <br /> address) 4 and hereby affir n that one of the <br /> following ftielhods will be used to meet the re ui i is of Flo ida Statutes(F.S.)515: <br /> Please initial the method(s)to be used for your pool. <br /> The pool will be isolated from access to the home by an enclosure that meets the pool ba rier requirements of <br /> F.S.515.29. <br /> The pool will be equipped with an approved,safety-pool cover that complies with ASTM 1346-91 (Standard <br /> Performance Specifications for Safety Covers for Swimming Pools,Spas,and Hot Tubs). <br /> xAll doors and windows providing direct access from the home to the pool and located within the <br /> enclosure/fence required by the Pasco County Land Development Code (LDC), Secti n 530.4(D), will be <br /> equipped with an exit alarm that has a minimum sound pressure rating of 85 decibels at t n feet. <br /> All doors providing direct access from the home to the pool and located within the enclosure/fence required by <br /> the Pasco County LDC,Section 530.4(D),will be equipped with self-closing,self-latching devices with release <br /> mechanisms placed no lower than 54 inches above the floor or deck. <br /> In addition to the enclosure/fence required by the Pasco County LDC, Section 530.4(0), a swimming pool <br /> alarm that,when placed in a pool,sounds an alarm upon detection of an accidental or unauthorized entrance <br /> into the water. Such pool alarm must meet and be independently certified to ASTM Standard F2208, titled <br /> "Standard Safety Specification for Residential Pool Alarms,"which includes surface motion,pressure,sonar, <br /> laser,and infrared alarms.For purposes of this paragraph,the term"swimming pool alarm"does not include <br /> any swimming protection alarm device designed for individual use,such as an alarm attached to a child that <br /> sounds when the child exceeds a certain distance or becomes submerged in water. <br /> I UNDERSTAND AND AGREE THAT NOT HAVING AT LEAST ONE OF THE ABOVE INSTALLED AT THE TIME OF <br /> FINAL INSPECTION OR WHEN THE POOL IS COMPLETED FOR CONTRACT PURPOSES WILL CONSTITUTE A <br /> VIOLATION OF F.S.515, AND WILL BE CONSIDERED AS COMMITTING, A MISDEMEANOR OF THE SECOND <br /> DEGREE,PUNISHABLE BY FINES UP TO$500.00 AND/OR UP TO 60 DAYS IN JAIL AS ESTABLISHED IN F.S.775. <br /> R4501.17.1.10: Where an aboveground pool structure is used as a barrier or where the barrier is mounted on top of the <br /> pool structure and the means of access is a ladder or steps,the ladder or steps shall either be capable of being secure, <br /> locked, or removed to prevent access, or the ladder or steps shall be surrounded by a barrier which meets the <br /> requirements of R4501.17.1.1 through R4501.17.19 and R4501.17.12 through R4501.17.14. When the ladder or steps <br /> are secured,locked,or removed,any opening created shall not allow the passage of a four-inch diameter sphere. <br /> I FURTHER UNDERSTAND AND AGREE THAT THE OWNER AND/OR CONTRACTOR WILL COMPLY WITH THE <br /> FOLLOWING REGULATIONS CONCERNING SWIMMING POOL, SPA, AND/OR HOT TUB ENCLOSURES <br /> IMMEDIATELY UPON COMPLETION OF THE SWIMMING POOL, SPA, OR HOT TUB, IN COMPLIANCE WITH THE <br /> PASCO COUNTY LDC,SECTION 530A(D): <br /> 1. Construct around the swimming pool, spa, or hot tub a MINIMUM FOUR-FOOT-HIGH FENCE with self-closing, <br /> self-latching gates. The fence must not have any gaps, openings, indentations, protrusions, or structural <br /> components that could allow a young child to crawl under,squeeze through,or climb over the fence. Gates must <br /> open outward,away from the pool area. The releasing mechanism of the latching device must be located on the <br /> pool side of the gate and so placed that it cannot be reached by a young child over the top or through any <br /> opening or gap. No opening in the fence may be large enough to admit a four-inch sphere. <br /> 2. Construct a screen enclosure around the swimming pool, spa, or hot tub with self-closing, self-latching, screen <br /> doors. Latches on exterior, screen doors must be a minimum of 54 inches from the exterior access standing <br /> surface. All screen enclosures require Building Permits. <br /> 3. Provide and utilize an approved,safety,swimming pool,spa,or hot tub cover that complies with ASTM F1346-91 <br /> (Standard Performance Specifications for Safety Covers for Swimming Pools, Spas,and Hot Tubs). Such cover <br /> must be capable of being securely fastened over the swimming pool,spa,or hot tub when not in use. <br /> 1 FURTHER UNDERSTAND AND AGREE THAT one of the enclosures described above will be completed prior to final <br /> inspection of the pool,spa,or hot tub. <br /> ADDITIONALLY, I FURTHER UNDERSTAND AND AGREE THAT the owner will require his/her pool contractor and <br /> his/her screen-enclosure contractor (if applicable) to request and successfully pass a final inspection immediately <br /> following the completion/installation of the swimming pool,spa,or hot tub. <br /> IF THE SIGNATURE of the contractor acting as agent for the owner appears below,the contractor promises in good faith <br /> to make the owner aware of the above-described requirements and penalties before commencing construction. <br /> publiddv/poolreq Page 1 of 3 <br />