Laserfiche WebLink
23. Tamper-Resistant Receptacles in accordance with 406.11 of the 2016 N.E:C <br /> 24. In accordance with the Land Development Code, lots-shall.be sodded before final at least 10 <br /> feet around the structure. <br /> 25:-R403.5.3Hot water.pipe insulation <br /> Insulation for fiotwater pipe With- minimum thermal resistance (.R-value) of R-3 shall.be applied to the <br /> -foliovuin <br /> 9-:: . <br /> Piping:-/;inch-(19.1 mm) and largerin.nominal diameter. <br /> Piping,serving more than-one dwelling unit: <br /> Piping located outside the conditioned space;. <br /> Piping from the'water heater to a distribution manifold. <br /> Piping:located under a floor slab. <br /> Buried in piping,' . <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25.Blower.door test shall be provided,before CO; <br /> 26.A cony of the energy.eacls shall be with permit at all times <br /> 27. Copy of final.insulation report shaff be provided ivith permit before rInaZ <br /> 28. No fence,pool or'screen enclosure .is-issued with ahis permit <br /> F.F.E:-Finished Floor Elevation <br /> F.B.C-..Florida Building Code 6t'Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans,with Disabilities Act . 'N.E.C.-National Electric Code-(2016) . <br />