Laserfiche WebLink
D <br /> Q <br /> r. <br /> { <br /> a. <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. F.RE...shall be a minimum of 8" above the road elevation and an engineered site plan. <br /> .2. 'Lots shall be graded to'coriiply with R401.3 of the F.B.C. <br /> 3. Compaction test required if 24"or more of fill dirt is brought in at any,one.place. <br /> 4. Tie in survey required before pouring concrete. <br /> 5. .Driveways require.a R.O.W. use permit. All 4 sides of driveway thra the sidewalk shall have <br /> expansion material. <br /> 6. All setbacks shall be met. <br /> 7. All property markers shall be uncovered and marked at time:of first inspection. <br /> 8: All A.D.A. requirements shall be met: <br /> 9-. No electric,.plumbing;mechanical,or framing shall be covered without an inspection and <br /> approval first. <br /> 10:.All Garages shall comply with section R302.6 of the F.B.-C. (Fire Separation): <br /> 11. Appliances shall not be installed in a location where subject to mechanical.damage unless <br /> protected by approved barriers. M303.4 of the F.B.0 <br /> 12. Water heaters shall comply with section P607.3 of the F.B.C: <br /> 13. Foundation supports for A/C units.shall be raised at least 3" above finished grade. M1.308:1 . <br /> 14. Return air in all bedrooms. F.B:C. M1620.4 <br /> 15. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C. <br /> 16. All glazing requirements are to be in accordance with R308:4 of the F.B:C. <br /> 17. All means.of egress are.to be in accordance with R311 of the F.B.C. <br /> 18. "Green gyp um board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. <br /> 19. Combination-type AM.breakers are required at all locations requiring an AM.type breaker. <br /> 20. Carbon nionokide.alarm-s will be re4uired in new construction that.iises fossil-burning heating <br /> or appliances or an attached garage. They shall be installed in accordance with the F.B.C: <br /> 21. All plumbing, mechanical; and electrical shall be separate from unit to unit. This includes all <br /> underground plumbing and electric. <br /> 22: All 2016 N.E.C. Codes will be enforced: <br />