Laserfiche WebLink
FORM`R405-2017 <br /> STATE COPY <br /> F PO:RII?- ENERGY EFFICIENCY CODE FOR BUtLDtNG CONSTRUCTION <br /> Florida.Department of Business and.Professional Regulation.- Residential.Performance.Method <br /> Project Name: KHO1464 Ashmere(TAM) Builder Name: K Hovnanian Homes <br /> Street: 6858 Shelby Lynn Way Permit Office: City of Zephyrhiils <br /> City;State,Zip: Zephyrhills,FL,32751 Permit Number: <br /> Owner. Jurisdiction: <br /> Design Location: FL;Tampa .County: Pasco.(Florida Climate-Zone•2) <br /> 1.`,New construction-or.existing New(From Plans) 9. .Wail Types(1.4.15.6.zgft.) Insulation Area <br /> _2...Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1248.00 ft2 <br /> b.Frame-Wood,Adjacent R=11.0 167.56 ft2. <br /> 3. Number of units,if multiple family 1 c.N/A R= ft2 <br /> 4. Number of Bedrooms 3 d.N/A R= ft2 <br /> 5. Is this a worst case? Yes 10.Ceiling Types (1464.0 sgft.) Insulation Area a.Under Attic(Vented) R=30.0 1464.00 ft2 <br /> 6. Conditioned.floor area.above.grade-(W). 1464. b-N/A R= ft? <br /> Conditioned floor area below grade(ft2) 0. c.N/A R= W <br /> 11.Ducts R ft2 <br /> 7. Windows(134.9 sgft.) Description Area a:Sup:Attic,Ret:Main,AH:Main 6 200 <br /> a. U-Factor. Dbl,U=0.34 78.75 ft2 <br /> SHGC: SHGC=0.23 <br /> b. U-Factor Dbl,U=0.63 40.00 ft2 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 22.3 SEER:15.00 <br /> c. U-Factor. Dbl,U=0.34 16.19 ft2 <br /> SHGC: SHGC=0.29 13.Heating systems kBtu/hr Efficiency <br /> d.. U-Factor. N/A ft2 a.Electric Heat Pump 23.2 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 3;668 ft. <br /> Area Weighted Average SHGC: 0.264 14.Hot water systems <br /> 8. Floor Types (1464.0 sgft.) Insulation Area a.Electric Cap:50 gallons <br /> EF:0.960 <br /> a.Slab-.On-Grade Edge Insulation R=0.0 1464.00 ft2 b. Conservation features <br /> b.N/A R= ft2 None <br /> c.N/A R= ft2 15:Credits-• Pstat' <br /> Glass/Floor Area: 0:092" Total Proposed..Modified-Loads-- 5.0-36- <br /> Total Baseline Loads: 50.31 PASS <br /> .1,h6reby:certify that the plans and specifications covered by Review of the plans and ��k1E STD <br /> .this calculation are in compliance with the Florida Energy specifications covered by this <br /> Code. calculation indicates compliance '� �r„ `` '" ,•�*..�� ` <br /> ,�i with the Florida Energy Code. <br /> PREPARED BY: /1 � j � Before construction is completed <br /> � . ... _ o <br /> DATE: A'-30-2 thist building will be inspected for <br /> compliance with Section 553.908 <br /> I:hereby certify that this building, as designed, is in compliance Florida Statutes. <br /> with: e.Florida Energy Code. �©!7 WS <br /> OWNER/AGENT: S0WCL7v2we,a/ BUILDING OFFICIAL: <br /> DRTE: 10/25/2020 DATE: <br /> - Compliance requires certification by the,air handler unit manufacturer that the air handier enclosure qualities as <br /> certifte fi.factory-sealed-itt.•accordance,with R401111: <br /> Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an <br /> envelope leakage test report with envelope leakage no greater than 7.00 ACH-60(R402A.1.2). <br /> 9130/2020 9:52 AIV1 EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition,(2017) Compliant Software .Page,1-of 4 <br />