Laserfiche WebLink
Legend for Construction Prints <br /> 0 Existing Overhead Install Overhead R/W C/L R IW <br /> Transformer Transformer 60' <br /> Existing Underground ' Install Underground <br /> Transformer � � Transformer <br /> I <br /> I I <br /> P Install Pedestal Install Recloser <br /> I I <br /> I <br /> i I <br /> - Existing Down Guy ) Install Down Guy FRONT YARD BACKLOT <br /> I <br /> O Existing Pole Install New Pole <br /> I I <br /> I <br /> Existing Fuse � I Install Fuse <br /> EOP EOP I <br /> Overhead Cable Closed Switch 17' 26' 17' <br /> I I <br /> GENERAL CONSTRUCTION NOTES <br /> - I <br /> DUKE ENERGYTO RESTORE RIGHTOF WAYTO EQUAL OR BETTERTHAN EXISTING <br /> CONDITION. <br /> P1 i P2 <br /> * TO AVOID CONFLICTS,CONTRACTOR WILL COORDINATE DEPTH OF UNDERGROUND APPROX.19' <br /> FACILITIES WITH THE MUNICIPALITY INSPECTOR PRIORTO BORES BEING INSTALLED. I TFMR I I I TFMR <br /> I I <br /> * MINIMUM DEPTH OF CABLE IN CONDUIT IS 36INCHES BELOW GRADE.THREE FEETOF S'EASEMENT S'SDWK 12'GRASS 12'GRASS S'SDWK S'EASEMENT <br /> SEPARATION FROM EXISTING UTILITIES AND STORM WATER/SEWERS REQUIRED. <br /> I I <br /> * ALL PULL BOX LIDS SHALL BETRAFFIC RATED WHEN INSTALLED WITHIN THE RIGHT OF WAY. <br /> I I <br /> CONTRACTOR SHALL MAINTAIN AN UNINTERRUPTED ACCESS TO ALL DRIVEWAYS, I <br /> SIDEWALKS AND SIDE STREETS ALWAYS,UNLESS OTHERWISE APPROVED ON THE MOT <br /> I <br /> I I <br /> PERMIT. I <br /> * A SEPARATE PERMITWILL BE REQUIRED FOR ANY SUBSURFACE TEST HOLES UNDER <br /> I <br /> PAVEMENT. I REPLACE 150'OF 1/0 AL UG PRIMARY CABLE IN 3" <br /> * DUKE ENERGYTO MAINTAIN 3 FEETMINIMUM COVER. I TYPICAL CROSS SECTION HDPE CONDUIT VIA DIRECTIONAL BORE FROM <br /> TRANSFORMER(P1)LOCATED IN 5'PLATTED I <br /> • ALLOTHER RIGHT OF WAY USERS AND MUNICIPALITIES IN THE IMMEDIATE VICINITY OF THE FOR CAMDEN AVE. EASEMENT CROSSING CAMDEN AVE TO <br /> PROPOSED CONSTRUCTION/INSTALLATION HAVE BEEN NOTIFIED IN WRITING. I LOOKING EAST TRANSFORMER(P2)LOCATED IN 5'PLATTED <br /> I EASEMENT IN BACK LOT I <br /> MINIMUM DEPTH OF CABLE AND CONDUIT UNDER SWALES AND DITCHES IS 3 FEET BELOW <br /> THE BOTTOM OF THE SWALES AND DITCHES. I <br /> I I <br /> MINIMUM HEIGHTOF OVERHEAD WIRES AND CABLE IS 18 FEETOVER ROADWAYS AND 16 <br /> FEET OVER DRIVEWAYS. � I <br /> **BEFORE DIGGING,CALL SUNSHINE @ 1(800)432-7770** EXIST UTILITY ABBREVIATIONS: PROJECT LOCATION: WO#34724126 <br /> f.�DUKE S-SEWER I R-RECLAIMED WATER I W-POTABLEWATER I G-GAS I E-ELECTRIC I CAMDEN AVE DRAWN: <br /> ENERGY. EXIST UTILITIES @ ASSUMED 36"MIN DEPTH,LOCATIONS ARE APPROXMATE C-COMMUNICATIONS,ALARM,SIGNAL,CABLES OR CONDUIT <br /> *NOT TO SCALE DATE:04/01/20 <br />