My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-982
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-982
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/25/2022 10:10:42 AM
Creation date
5/25/2022 10:10:40 AM
Metadata
Fields
Template:
Building Department
Company Name
DUKE ENERGY
Building Department - Doc Type
Permit
Permit #
20-982
Building Department - Name
DUKE ENERGY
Address
MIS SEE DESCRIPTION CAMDEN AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SYMBOLS: <br /> ® Work Area <br /> • Channelizing Device(See Index 102-600) <br /> [b Work Zone Sign Buffer <br /> Space 250' C B A <br /> LT' Flagger See <br /> �j Lane Identification+Direction of Traffic Table 1 D <br /> ROAD <br /> PREPARED �qQ p E WORN <br /> T06TOP nn AIIFAp AHEAD ,n <br /> a a <br /> b Work Area b <br /> Tangent Device Spacing(See Table 1) <br /> ROAD ONEOUE BE <br /> • WORK <br /> aRewD t�Dy iosmm n Taper Length <br /> D 50,To 100' x May Be omitted if ROAD WORK AHEAD sign is installed upstream within the project limits. <br /> A B C <br /> WITHOUT TEMPORARY RAISED RUMBLE STRIPS <br /> GENERAL NOTES: <br /> 4.When a side road intersects the highway within the TTC zone,place TABLE I <br /> and the following sheets: <br /> 1.Special Conditions may be required in accordance with these notes additional TTC devices in accordance with other applicable TCZ Indexes. DEVICE SPACING <br /> S.The two channelizing devices directly in front of the work area may be Maximum Spacing Distance <br /> A.Railroad Crossings: p clog Maximum Spacing of <br /> omitted provided vehicles in the work area have high-intensity rotating, Between <br /> a.If an active railroad crossing is extend <br /> eBcloser to the Work Area than Posted of Canes ke Type l or Type 11 Buller <br /> the queue length plus 300 feet,extend the Buffer Space as shown on flashing,oscillating,or strobe lights operating. Speed Tubular Markers Barricades/Panels/Drums Signs Space <br /> Sheet 3. p <br /> b.If the queuing of vehicles across an active railroad crossing cannot be 6.When Buffer Spare cannot be attained due[o geometric constraints,use <br /> q 9 9 the greatest attainable length,not less than 200 ft,for posted speeds On a On a On a On a <br /> avoided,provide a uniformed[raflic control officer or flagger a[the greater than 25 mph. Taper Tan en[ Taper Tangent A 8 C D <br /> highway-rall grade crossing to prevent vehicles from stopping within 25 20' SO 20' S0' 20O 200 200' 700' 155' <br /> thedew highway frail grade crossing, <br /> even if automatic[rain warning 7,ROAD WORK AHEAD and the BE PREPARED TO STOP signs may be omitted if <br /> devices are in place. 30 20' 50' 20' 50' 2001 200' 200' 100' 200' <br /> B.If the Work Area encroaches on the Centerline,use the Layout for all 01 the following conditions are me[: <br /> Temporary Lane Shift to Shoulder on Sheet 3 only if the Existing 35 20' S0' 20 50, 200' 200' 200' 100' 250' <br /> Paved Shoulder width is sufficient to provide for an 11'lane A.Work operations are 60 minutes or less. 40 20' 50, 20' 50' 200' 200' 200' 700' 305' <br /> between the Work Area and the Edge of Existing Paved Shoulder. B.Speed limit is 45 mph or less. <br /> Reduce the posted speed when appropriate. C.There are no sight obstructions to vehicles approaching the work area for 45 20' 50' 20' 50, 350' 350' 350' 17S 360' <br /> a distance equal to the Buffer Space shown in Table 1. 50 20' 50' 20' 106' 500' SO& 50U 250' 425' <br /> 2.Temporary Raised Rumble Strips: D.Vehicles in the wort area have high-intensity,rotating.flashing,oscillating, <br /> or strobe lights operating. 55 20 50' 20 100' 2640' 1500 1000' 500' 495' <br /> A.Use when both of the following conditions are met concurrently: E.Volume and complexity of the roadway has been considered. 60 20' 50' 20' too, 1640' 1500' 1000' 500' 570' <br /> a. Existing Posted Speed is 55 mph or greater; F.If a railroad crossing is present,vehicles will not queue across rail tracks. 65 20' 50' 20' 100' 2640' 1500 1000' S00' 645' <br /> b.Work duration is greater than 60 minutes. G.AFADs are not in use. <br /> B.Use a consistent Strip color throughout the work zone. 70 29 50' 20' 100' 2640' I500' 1000' 500' 730' <br /> C.Place each Rumble Strip Set transversely across the lane at locations B.See Index 102-600 for general TCZ requirements and additional information. <br /> shown. 9.Automated Flagger Assistance Devices(AFADs)may be used in accordance <br /> throughooutut work zone. <br /> D.Use Op[ 1 or Option 2 as shown on Sheet 2.Use only one option with Specifications Section 102,990 and the APL vendor drawings. <br /> 3.Additional one-way control may be provided by the following means: CONDITIONS <br /> A.Fla parrying vehicle: WHERE ANY VEHICLE,EQUIPMENT, <br /> B.Official vehicle; <br /> C.Pilot vehicles; WORKERS OR THEIR ACTIVITIES <br /> D.Traffic signals. ENCROACH THE AREA BETWEEN <br /> When flaggers are the sole means of one-way control,the flaggers THE CENTERLINE AND A LINE 2' <br /> must be in sight of each other or in direct communication at all times. OUTSIDE THE EDGE OF TRAVEL WAY. <br /> Q <br /> LAST 2 DESCRIPTION: FY 2019-20 INDEX SHEET <br /> REVISION FDOT TWO-LANE, TWO-WAY, <br /> H/01/17 W O STANDARD PLANS WORK WITH INTHETRAVELWAY 102-603 1 of 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.