Laserfiche WebLink
23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2016 N.E:C <br /> 24. In accordance with the Land Development Code, lots shall be sodded before firial at least 10 <br /> feet arounS the structure. <br /> 25. R403.5.3Hot water pipe insulation <br /> Insulation for hot water pipe with a minimum thermal resistance (R-value) of R-3 shall be applied to the <br /> following: <br /> Piping V. inch (19.1 mm) and larger in nominal diameter. <br /> Piping.serving more than one dwelling unit. <br /> Piping located outside the conditioned space. <br /> Piping from the water heater to.a.distribution manifold:. <br /> Piping.located under a floor slab. <br /> Buried in piping. <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25.Blower door test shall be provided before C.O: <br /> 26.A copy of the enerjy-cacls shall be with permit at all times <br /> 27. Copy of final insulation-report shall be provided with Permit before final <br /> .28. No fence, pool or screen enclosure :is issued with:this Permit <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C-Florida Building Code 6 h Edition <br /> R.O.W.-Right of Way <br /> A.D:A.=.Americans with Disabilities Act N.E.C.-National Electric Code (2016) <br />