Laserfiche WebLink
23. Tamper-Resistant Receptacles in accordance with 406.11 of the 2016 N.E.0 <br /> 24. In accordance with the Land Development Code, lots shall be sodded before final at least 10 <br /> feet around the structure. <br /> 25. R403.5.3Hot water.pipe insulation <br /> Insulation for hot water pipe with a minimum thermal resistance (R-value) of R-3 shall.be applied to the <br /> following:: <br /> Piping 3/; inch (19.1 mm)and larger in nominal diameter.. <br /> Piping serving more than one dwelling unit. <br /> Piping located outside the conditioned space. <br /> Piping ftprn the water heater to.a distribution manifold: <br /> Piping:located under a floor slab: <br /> Buried in piping. <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25. Blower door test shall be provided before C.O: <br /> 26.A copy of�the enemy cacls shall be with permit at all times <br /> 27. Copy of final insulation report shall be provided with permit before rnaL <br /> 28.No fence,pool or screen enclosure :is issued with:this permit <br /> F.F.E.-Finished Floor Elevation <br /> F.B.G.•Florida Building Code 6a'Edition <br /> R.O.W.-Right of Way <br /> A.D:A.-.Americans with Disabilities Act N.E.C.-National Electric Code(2016) <br />