Laserfiche WebLink
PGT Industries,Inc. <br /> NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED <br /> A. DRAWINGS <br /> 1. Manufacturer's die drawings and sections. <br /> (Submitted tinder NOA X6. 11-0107.09) <br /> 2. Drawing No. SGD-5470, titled"Vinyl Sliding Glass Door NOA (NI)", sheets I through 21 of <br /> 21,prepared by manufacturer,dated 10105115,with Revision A dated 04/05/17, signed and <br /> scaled by Anthony L. Miller,P.E. <br /> B. TESTS <br /> 1. Test report on 1)Air Infiltration Test,per FBC,TAS 202-94 <br /> 2)Uniform Static Air Pressure Test,per FBC,TAS 202-94 <br /> 3)Water Resistance Test,per FBC,TAS 202-94. <br /> 4)Forced Entry Test,per FBC,TAS 202-94 <br /> along with marked-up drawings and installation diagram of vinyl sliding glass door,prepared by <br /> Fenestration Testing Lab, Inc.-,Test Report No. FTL 6637(samples A-1 thru A-5), dated 11/19/10, <br /> signed and sealed by Jorge A. Causo,P. E. <br /> (Submitted under NOA No. 11-010 7.09) <br /> 2. Additional test report No. FTL 6638 (samples A-I thru A-22)per TAS 201/203-94, issued by <br /> Fenestration Testing Lab,'Inc., dated 11/19/10, signed and sealed by Jorge A. Causo,P.E. <br /> (Submitted tinder NOA No. 11-010 7.04) <br /> 3. Additional test report No.,FTL 8717,issued by Fenestration Testing Lab, Inc., dated 12/07/15, <br /> revised on 02/15/16 and 0/24/16, signed and scaled by Idalmis Ortega,P. E. <br /> (Submitted tinder NOA No. 15-1210.01) <br /> 4. Additional test report No.iFTL 8546 issued by Fenestration Testing Lab, Inc., dated 11/06/15, <br /> revised on 01/04/16 and 02/11/16,signed and sealed by Idalmis Ortega,P. E. <br /> (Submitted under NOA No. 15-1210.01) <br /> 5. Additional test report No.'FTL 8547 issued by Fenestration Testing Lab,Inc.,dated 12/04/15, <br /> revised on 02/15/16, signed and sealed by Idalmis Ortega,P. E. <br /> (Submitted under NOA No. 15-1210.01) <br /> 6. Additional test report No.FTL 8548 issued by Fenestration Testing Lab, Inc., dated 12/04/15, <br /> revised on 01/04/16 and 02/11/16, signed and sealed by Idalmis Ortega,P. E. <br /> (Submitted under NOA No. 15-1210.01) <br /> 7. Additional test report No. FTL 8549 issued by Fenestration Testing Lab, Inc., dated 12/04/15, <br /> revised on 12/04/15 and 02/11/16, signed and sealed by Idalmis Ortega, P.E. <br /> (Submitted under NOA No. 15-1210.01) <br /> 8. Additional test report No. FTL 8552 issued by Fenestration Testing Lab, Inc., dated 12/04/15, <br /> revised on 02/15/16,signed and sealed by Idahnis Ortega,P. E. <br /> (Submitted tinder NOA No. 15-1210.01) <br /> C. CALCULATIONS <br /> 1. Anchor verification calculations and structural analysis, complying with FBC-2014,prepared by <br /> PGT, dated 12/09/15 and last revised on 02/15/16, signed and scaled bV Anthony L.Miller, P.E. <br /> (Submitted under NOA N6. 15-1210.02) <br /> Jorge M.Plasencia,P.E. <br /> Product Control Unit Supervisor <br /> NOA No. 17-0420.07 <br /> Expiration Date: April 21,2021 <br /> Approval Date: September 28,2017 <br /> E-1 <br />