My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-1025
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-1025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/26/2022 2:18:47 PM
Creation date
5/26/2022 2:18:46 PM
Metadata
Fields
Template:
Building Department
Company Name
LENNAR HOMES LLC
Building Department - Doc Type
Permit
Permit #
20-1025
Building Department - Name
LENNAR HOMES LLC
Address
2831 LYTTON HALL DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Q <br /> ti <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. F.F.E; shall be a minimum of 8" above the road elevation and an engineered site plan. <br /> I Lots shall be graded to comply with R401.3:of the F.B.C: <br /> 3: Compaction test required if 24"or more of fill dirt is brought in at any one place. <br /> 4: Tie in survey required before pouring concrete. <br /> -5. Driveways require a R.O.W.use permit. All 4 sides of driveway thru the sidewalk shall have <br /> expansion material. <br /> 6: All setbacks shall be met. <br /> 7: All property markers shall be uncovered,and marked at time of first inspection. <br /> 8: All A.D.A.-requirements shall be met. <br /> 9. No electric,.plumbing;mechanical, or framing shall.be covered without an inspection and <br /> approval first. <br /> 10, All Garages shall comply with section R302:6 of the F.B.C. (Fire Separation). <br /> . . <br /> 11. Appliances shall not be installed in a location where subject.to mechanical damage unless <br /> protected,by approved barriers. M303:4 of the RB.0 <br /> .12. Water heaters shall comply with section P607.3 of the F:B:C: <br /> 13. Foundation supports for A/.0 units shall.be raised at least 3" above finished grade. M1308.1 <br /> 14: Return air in all bedrooms. F.B.C. M1620.4 <br /> 15. Smoke detectors are to be installed in accordance with R3.13:1 of the F.B.C. <br /> 16. All glazing requirements are to be-in accordance'with R308A.0f the F.B:C: <br /> .17. All means.of egress are.to be-in accordance with R311 of the F.B.C: <br /> 18. "Green gypsum board" shall riot be used as a backer in showers or tubs:R702:4.2 F.B.C. . <br /> 10. Combination-type AM breakers are.required-at all locations requiring an AM type breaker. <br /> 20. Carbon monokide alarms will be required in new construction that uses fossil-burning heating <br /> or appliances or an-attached garage. They shall be installed in accordance with the F.B.C. <br /> 2_1. All plumbing,mechanical, and electrical shall'be separate from unit to unit: This includes all <br /> underground.plumbing and electric. <br /> 22. All 20M N.E.C. Codes will be enforced: <br />
The URL can be used to link to this page
Your browser does not support the video tag.