Laserfiche WebLink
/ Single Phase Inverter <br /> with H D-Wave Technology for North America <br /> SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/ <br /> I <br /> SE760OH-US / SE10000H-US / SE1140OH-US <br /> OUTPUT <br /> Rated AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 @ 240V VA <br /> 3300 @ 208V 5000 @ 208V 10000 @ 208V <br /> Maximum AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 @ 240V VA <br /> 3300 @ 268V 5000 @ 208V 10000 @ 208V <br /> AC Output Voltage Min.-Nom.-Max. <br /> ✓ ✓ ; ✓ ✓ ✓ ✓ ✓ <br /> (211-240-264) Vac <br /> AC Output Voltage Min.-Nom.-Max. ✓ ✓ ✓ Vac <br /> (183-208-229) <br /> AC Frequency(Nominal) j 59.3-60-6051 Hz <br /> Maximum Continuous Output i <br /> Current @240V 12.5 16 f 21 25 32 42 47.5 A <br /> Maximum Continuous Output _ <br /> Current @208V 16 24 48.5 A <br /> GFDI Threshold 1 A <br /> Utility Monitoring,Islanding Protection, Yes <br /> Country Configurable Thresholds <br /> INPUT <br /> Maximum DC Power @240V 4650 5900{ 7750 9300 11800 15500 17650 W <br /> Maximum DC Power @208V - 5100 j 7750 15500 W <br /> Transformer-less,Ungrounded Yes <br /> Maximum Input Voltage i 480 Vdc <br /> Nominal DC Input Voltage j 380 400 Vdc <br /> Maximum Input Current @240V91 8.5 10.5 1 13.5 16.5 20 27 30.5 Adc <br /> Maximum Input Current @208VR) 9 13.5 27 Adc <br /> Max.Input Short Circuit Current 45 Adc <br /> Reverse-Polarity Protection Yes <br /> Ground-Fault Isolation Detection 600ksr Sensitivity <br /> Maximum Inverter Efficiency 99 99.2 % <br /> CEC Weighted Efficiency j 99 99 @ 240V % <br /> 1 98.5 @ 208V <br /> Nighttime Power Consumption j <2.5 I W <br /> ADDITIONAL FEATURES j <br /> Supported Communication Interfaces RS485,Ethernet,ZigBee(optional),Cellular(optional) <br /> Revenue Grade Data,ANSI C1220 Optional(" <br /> Rapid Shutdown-NEC 2014 and Automatic Rapid Shutdown upon AC Grid Disconnect <br /> 2017 690.12 <br /> STANDARD COMPLIANCE <br /> Safety ,UL1741,UL1741 SA,UL1699B,CSA C22.2,Canadian AFCI according to T.I.L.M-07 <br /> Grid Connection Standards IEEE1547,Rule 21,Rule 14(HI) <br /> Emissions FCC Part 15 Class B <br /> INSTALLATION SPECIFICATIONS <br /> AC Output Conduit Size/AWG Range I"Maximum/14-6 AWG 1'Maximum/14-4 AWG <br /> DC Input Conduit Size/#of Strings/AWG Range ;1"Maximum/1-2 strings/14-6 AWG 1"Maximum/1-3 strings/14-6 AWG <br /> Dimensions with Safety Switch 17.7 x 14.6 x 6.8 /450 x 370 x 174 21.3 x 14.6 x 7.3/540 x 370 x 185 In/ <br /> (HxWxD) mm <br /> Weight with Safety Switch 22110 25.1/11.4 1 26.2/11.9 38.8/17.6 lb/kg <br /> Noise <25 <50 dBA <br /> Cooling Natural Convection <br /> Operating Temperature Range -13 to+140/-25 to+60t4l(-40'F/-40'C option)(=) `F/-C <br /> Protection Rating NEMA 4X(Inverter with Safety Switch) <br /> 'For other regional settings please contact SolarEdge support <br /> �A higher current source may be used;the inverter will limit its input current to the values stated <br /> �Revenue grade inverter P/N:SEx H-USOOONNC2 <br /> For <br /> power de-rating information refer to:https,//v .solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf <br /> s-40 version P/N:SEocxxH-US000NNU4 <br /> 2.SolarEdge Technologies,Inc.All rights reserved.SOLAREDGE the S01arEdge logo,OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies,Inc.All ® <br /> other trademarks mentioned herein are trademarks of their respective owners.Date:03/2019N Ill®H01/ENG NAM.Subject to change without notice. S <br /> I <br />