Laserfiche WebLink
i <br /> 23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2016 N.E.0 <br /> 24. In accordance with the Land Development Code, lots shall be sodded before final at least 10 <br /> feet around the structure. <br /> 25. R403.5.3Hot wate.rpipe insulation. <br /> Insulation for hot water pipe with a minimum thermal resistance (R-value) of R-3 shall be applied to the <br /> following: <br /> Piping.V, inch (.19.1 mm) and larger-in nominal diameter. <br /> Piping.serving more than,one dwelling unit. <br /> Piping located.outside the conditioned space. <br /> Piping from the:water heater to a distribution manifold. <br /> Piping located under a floor slab. <br /> Buried in piping. <br /> Supply and return piping iri recirculation systems other thart demand recirculation systems. <br /> 25:Blower:door test shall be provided before C.O: <br /> 26.A copy of the enemy cacls"shall be ivith permit at all times <br /> 27. Co&-of final'insulation reyort shall be provided with permit before fnab <br /> 28. No fence, pool or screen-enclosure :is issued with This permit <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C-.Florida Building Code 6ffi Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2016) <br />