Laserfiche WebLink
23..Tamper- Resistant Receptacles in accordance with 406.11 ofthe 2016 N.E.0 <br /> 24. In accordance with the Land Development Code,lots shall be-sodded before final at least 10 <br /> feet around the structure. <br /> 25..R403.5.3Hot water pipe insulation. <br /> insulation for hot water pipe with'a minimum thermal resistance (R-value) of R-3.shall,be applied to the <br /> following: <br /> Piping-1.inch (19.1 mm)and larger in.nominal diameter. <br /> Piping serving more than one dwelling unit. <br /> Piping located outside the conditioned space:. <br /> Piping from the water heater to a distribution manifold:. <br /> Piping:located under a floor slab. <br /> Buried in piping,. <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25. Blower:door test shall be provided before C.O: . <br /> 26. A cony of'the enerffy eacls shall be Wth'penv it at all times <br /> 27.. Cony of final insulation report shall be provided with permit before fnaL <br /> 28. No fence,- <br /> Pool or'screen enclosure :is issued with:this pernift. <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C- Florida Building Code 6t'Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2016) <br />