Laserfiche WebLink
23.-Tamper=Resistant.Receptacles in accordance with 406.11 ofthe 2016 N.E.0 <br /> 24. In accordance with the Iarid Development Code, lots shall be sodded before final at least 10 <br /> feet around the structure. <br /> 25. R403.5.3Hot water.-pipe insulation <br /> Insulation for_hot.Water pipe with a minimum thermal-resistance (R-value) of R-3 shall.tie applied to the <br /> following: <br /> Piping�1.inch (19.1 mm)and larger in.nom Mal diameter. <br /> Piping serving more than one dwelling unit. <br /> Piping located outside'the conditioned space:_ <br /> Piping from the:water"heater to:a distribution manifold:. <br /> Piping located under a floor slab: <br /> Buried in piping. <br /> Supply and return piping in recirculation systems other than demand recirculation systems, <br /> 25: Blower:door test shall be provided before C,O: <br /> 26 A copy of the enemy.cacls'shall be with'permit at all tunes <br /> 27. Copu ofrinal.:insulation report-sli alhbe provided ivith permit before rinaL <br /> 28.No fence,pool onscreen enclosure :is issued with ahis permit <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C-:Florida Building Code 6ffi Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-.Americans with Disabilities.Act N.E.C.-National Electric Code (2016) <br />