D <br /> r_ <br /> y t <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. F:F.E.. shall be a minimum of 8"above the road elevation and an engineered site plan. <br /> 2: Lots shall be graded:to comply with R-401.3 'of the F.B.C. <br /> 3: Compaction test required if 24" or more of fill dirt is brought in at any one-place. <br /> 4: Tie in survey required before pouring concrete. <br /> 5. -Driveways require a R.O.M. use permit. A114 sides of driveway thru the sidewalk-shall have <br /> expansion material. <br /> 6: .All setbacks shall be met. <br /> -1. All property:markers shall be uncovered and marked at time of first inspection. <br /> 8: All A.D.A.requirements shall be met: <br /> 9-. No electric, plumbing, in or framing shall be covered without an inspection.and <br /> approval first. <br /> 10: All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation): <br /> 11. Appliances shall not be installed in a location where subject to mechanical damage unless <br /> protected by approved barriers. M303.4 of the F.B.0 <br /> 12. Water heaters shall comply with section P607.3 of the .&C. <br /> 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M 1308.1 <br /> 14. Return air in all bedrooms. F.B:C. M1620.4 <br /> 15. Smoke detectors are to be installed in accordance with R3.13:1 of the F.B.C;. <br /> 16. All glazing requirements are to be in accordance with R308:4 of the F.B:C: <br /> 17. All means of egress are to be in accordance_with R311 of the F.B.C. <br /> 18. "Green gypsum board" shall not be used as,!backer in showers or tubs. R702.4.2 P.B.C. <br /> 19: Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. <br /> 20. Carbon monoxide alarms will be required in-new construction that uses fossil-burning he <br /> or appliances or an attached garage.' They shall be installed in accordance with the F.B.C: <br /> 21. All plumbing,mechanical, and electrical shall be separate from unit to unit. This includes all <br /> underground plumbing and electric. <br /> 22. All 2016 N:E.C. Codes will be enforced: <br />