Laserfiche WebLink
D <br /> Q' <br /> ti <br /> i <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. F.F.E.. shall be a minim6m of 8"above the road elevation and an engineered site plan. <br /> 2. Lots shall be- graded to.comply with-R401.3.of the.F.B.C. <br /> 3. Compaction test required if 24".or more of fill dirt is brought in at any one place. <br /> 4. Tie in survey required before pouring concrete. <br /> .5. Driveways require.a R.O.W. use_ perm_it: All 4 sides_ of driveway thru the sidewalk shall have <br /> expansion material. <br /> 6. All setbacks shall be met. <br /> 7. All property markers shall be uncovered and marked at time of first inspection. <br /> 8: All AD.A.requirerrients shall be met: <br /> 9. No electric, plumbing, mechanical, or.framing shall be:covered without an inspection and <br /> approval first. <br /> 10. All.Garages shall comply with section R302.6 of the F.B.C. (Fire Separation). <br /> 1 I.. Appliances shall not be installed in a location where subject to mechanical damage unless <br /> protected by approved barriers. M303.4 of the F.B.0 <br /> 12. Water heaters shall comply with section P607.3 of the F.B.C. <br /> 13.-Foundation supports for A/C units shall b:e-raised at least 3" above finished grade. M1308.1 <br /> 14, Return air in all bedrooms. F.B.C. M1620.4 <br /> 1-5. Smoke detectors are to be installed in accordance with R3111 of the.F.B.C. <br /> 16.-All glazing requirenients are to b.e in accordance with R308.4 of the F.B.C: <br /> 17. All means of egress are to be in accordance with R311 of the F.B.C. <br /> 18. `-`Green gypsum board"shall not be used as a backer in showers or tubs. R702A.2 F.B.C. <br /> 19:.Combinatiori-type AFCI breakers are required at all locations requiring an AFCI type breaker. <br /> 20. Carbon monoxide alarms will be required in' new construction that uses fossil-burning heating or-appliances or an attached garage. They shall be installed in accordance with the F.B.C: <br /> 21. All plumbing, mechanical, and electrical shall'be separate.from unit to unit: This includes all <br /> underground plumbing and electric. <br /> 22. All 2016 N.E.C. Codes will be enforced. <br /> 1 <br />