Laserfiche WebLink
23. Tamper- Resistant Receptacles in accordance with 406.11 ofthe 2016 N.E.0 <br /> 24. In accordance with the Land Development Code,lots shall.be sodded before final at least 10 <br /> feet around the structure. <br /> 25-. R403.5.3Hot water pipe insulation <br /> Insulation for hot water'pipe with a minimum thermal resistance (R-__Value) of R-3 shall.be applied to the <br /> followin <br /> Piping 31.inch (19.1 mm) and larger in nominal.diameter. <br /> Piping serving more than.one dwelling unit. <br /> Piping located outside'the conditioned space. <br /> Piping from the:water'heater to a distribution manifold: <br /> Piping:located under.a floor slab. <br /> Buried in piping.' <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25.Blower door test shall be provided before C.O: <br /> 26.A cony of the enerzy:cacls shall be with permit at all times. <br /> 27. Cone of final'insulation report shall be provided with Permit before rInal <br /> 28.No_fence,-pool or screen enclosure :isissued with.thisperm:it <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C- Florida Building Code 6a'Edition <br /> R.O.W.-Right of Way <br /> A.D.A.=Americans with Disabilities Act N.E.C.-National Electric Code (2016) <br />